Télécharger Imprimer la page

Geberit 616.211.00.1 Manuel D'entretien page 17

Publicité

Operation
Display of operating state
The operating state of the Geberit sanitary flush is
displayed on the control unit. The control unit is
accessible once the cover plate has been
detached. → See
1
, page 105.
Figure 2: Displays and controls on the control unit
1
Green LED <OK>
2
Red LED <Err>
3
<Test> button
4
Buzzer
Table 3:
Operating states
Element
Status
Short flash
pulse
Long flash
Green
pulse
LED
On
Off
On
Red LED
Flash pulse
Off
2)
On
1)
Buzzer
Off
45035999171656331-1 © 06-2019
966.709.00.0(03)
All manuals and user guides at all-guides.com
Meaning
Normal operation,
operating voltage on
Normal operation,
3)
Bluetooth® interface
active
Solenoid valve open
Operating voltage off
Malfunction, diagnose
with Geberit SetApp
Warning, diagnose with
Geberit SetApp
Normal operation
Malfunction, diagnose
with Geberit SetApp
Normal operation or
buzzer deactivated
Element
Status
<Test>
Press the
button
button
1)
The buzzer is deactivated at the factory. If required,
activate <Basic settings> in the menu.
2)
The buzzer can be suppressed by pressing the
<Test> button. If the malfunction continues for longer
than 24 hours, the buzzer will automatically reactivate.
3)
The Bluetooth® brand and its logos are the property
of Bluetooth SIG, Inc. and are used under license by
Geberit.
Operation with Geberit SetApp
The Geberit sanitary flush and malfunction diagnosis
are operated using a smartphone that has the Geberit
SetApp. The Geberit SetApp is available free of
charge for iOS and Android smartphones in the
respective app stores (see QR code).
The app communicates via a Bluetooth® interface
with the Geberit sanitary flush.
Installing the Geberit SetApp:
app.geberit.com/setapp
Meaning
Test solenoid valves.
If Bluetooth® interface is
active: disconnect
connection.
In the event of an active
malfunction: suppress
buzzer.