Télécharger Imprimer la page

PRESIDENT JOHNSON III Manuel D'utilisation page 33

Publicité

8) ANL/NB ~ HI-CUT/NRC~ M2
NB/ANL
(short press)
ANL: Automatic Noise Limiter / NB: Noise Blanker. These filters allow to reduce
the background noise and some receiving interferences. Each short press
turns in a loop: 1. ANL on / NB off • 2. ANL off / NB on • 3. ANL and NB on •
4. ANL and NB off. When a filter is active its "ANL" or "NB" icon is displayed.
In FM mode, only NB on and NB off. ANL is not displayed.
HI-CUT
(long press)
Hi-Cut: Suppression of high frequency interferences. To use according to
the receiving conditions. A short pressure activates the HI-CUT filter and
«HI-CUT» appears on the display. A new push disables the function and
«HI-CUT» disappears.
NRC
This switchable filter can be used to improve the reception and
transmission modes.
-
Press the F button (5) once briefly.
-
Press the NRC button (8) briefly a second time to activate/deactivate.
NRC SETTINGS
The NRC filter can be set independently in transmission (TX) as in reception
(RX).
-
Press the F button (5) once briefly.
-
Press and hold the NRC button (8) a second time to access the NRC
SETTINGS screen (NRC flashes on the display).
-
Use the s and t or UP/DN (12) buttons on the microphone to change
the reception of the transmission value of the filter from 01 to 05 or OF
to deactivate it.
-
Press the NRC button again briefly to confirm your choice.
-
Press the F button to toggle between the NRC TX t / RX r settings.
The default values for the NRC filter are 03 for transmission and reception.
M2
(see § MEM on page 31)
appears on the display.
appears on the display.
9) VOX ~ VOX SET ~ M1
VOX
(short press)
The VOX function allows
transmitting
phone (or in the optional vox microphone) without pressing the PTT switch
(12). The use of an optional vox microphone connected to the rear panel
of the transceiver (D)
disables
Press the VOX (9) key in order to
on the display. Press again the VOX key (9) to
disappears.
VOX SET
(long press)
1. Long press the VOX SET key (9) to
the current setting and its value appear on the display. Three parameters
allow to adjust the VOX: Sensitivity L / Anti-vox level A / Vox delay time t.
2a. Use the s/t key on the front panel or the UP/DN key (4) on the micro-
phone to
modify
the current parameter then, press the VOX key (9) to
select
the next parameter or....
2b. Press first the VOX key (9) to
the s/t key on the front panel or the UP/DN key (4) on the microphone
to
modify
the current parameter.
3. When all adjustments are done, long press the F key (5) to
If the KEY BEEP function is activated, a long beep sounds to
the success of the operation (see § KEY BEEP page 34).
4. If no key is pressed for 10 seconds, the unit automatically
function VOX SETTING without saving.
-
Sensitivity L: allows the adjustment of the microphone (original one or
optional vox) for an optimum transmission quality. Adjustable level from1
(high level) to 9 (low level). Default value: 1.
-
Anti-Vox A: allows disabling the transmission generated by the surrounding
noise. The level is adjustable. AF (according the squelch level) and from
0 (without anti-vox) to 9 (low level). Default value: AF.
-
Delay time t: allows avoiding the sudden cut of the transmission by
adding a delay at the end of speaking. The level is adjustable from 1
(short delay) to 9 (long delay). Default value: 5.
VOX SETTING doesn't activate the VOX function.
M1
(see § MEM on page 31)
33
by speaking into the original micro-
the original microphone.
activate
the VOX function. "VOX" appears
disable
the function. "VOX"
enter
the VOX SETTING. "VOX" blinks,
select
another parameter and then use
store
and exit.
confirm
exits
the

Publicité