Goodwe A-MS Serie Instructions D'installation
Goodwe A-MS Serie Instructions D'installation

Goodwe A-MS Serie Instructions D'installation

Publicité

Liens rapides

PV Master App
SEMS Portal App SEMS Portal website
www.semsportal.com
JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO.,LTD
No. 90 Zijin Rd., New District, Suzhou, 215011, China
www.goodwe.com
service@goodwe.com
LinkedIn
Offical website
340-00454-01
A-MS QUICK INSTALLATION INSTRUCTIONS
Version: 1.1
Date: 2021-05-31

Publicité

loading

Sommaire des Matières pour Goodwe A-MS Serie

  • Page 1 PV Master App SEMS Portal App SEMS Portal website LinkedIn Offical website www.semsportal.com A-MS QUICK INSTALLATION INSTRUCTIONS JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO.,LTD No. 90 Zijin Rd., New District, Suzhou, 215011, China Version: 1.1 www.goodwe.com 340-00454-01 Date: 2021-05-31 service@goodwe.com...
  • Page 2 Product Overview Wi-Fi LED Indicators Reset/Reload DC switch[1] On-Grid terminal (GRID) PV input terminal (PV INPUT) Ground bar Ground bar EMS (EMS) [2] Meter CT terminal (Meter) Hole for Hole for connecting cable connecting cable Port for connecting WiFi Module Note: [1] DC switch: DC switch is used to shut down the PV system in case of emergency.
  • Page 3 Installation Requirements Install the inverter Fasten screws Installation angle Installation space 500mm (19.69 in.) (7.87 in.) (7.87 in.) (11.81 in.) 200mm 200mm 300mm Inverter could be locked for anit-theft (11.81 in.) 300mm Installation angle (7.56 in.) 415mm (16.34 in.) 192mm (19.69 in.) Upward----------500mm (11.81 in.)
  • Page 4 Avant de commencer l’installation ou la mise en service de A-MS, DANGER! PV cable assembly and connection veuillez lire attentivement les déclarations ci-dessous. Max 5.6mm (0.22 in.) DANGER! • Pendant la connexion au câblage, l’opérateur doit toujours 90℃ wire, 12AWG copper porter un EPI approprié.
  • Page 5 On-grid cable assembly and connection System Connection Diagram Max 7.4mm (0.29 in.) This diagram is an example for US split-phase grid system. 90℃ wire, 8-10AWG copper 18mm (0.71 in.) Cable Terminal CT connection Grid Power Meter CT 2 CT 1 CT 1 connect to L1 WiFi module CT 2 connect to L2...
  • Page 6 Wiring System Powering On the System 1. Close the AC breaker between inverter and Safety code: the grid. After connecting Solar-WiFi* (*The Wi-Fi 2. Turn on the DC switch. signal is named the last 8 characters of the 3. Observe operation status of the inverter via LED indicators.