venting requirements
EN
12"
MINIMUM
30"
MINIMUM
MAXIMUM 10FT VENT LENGTH
INSTALLATION
0.8cm)
MUM
2.1.1 corner termination
The maximum vent length for a corner installation is 20" (50.8cm) of horizontal run, in addition to the 45° offset. In
this case, 0" rise is acceptable when using rigid venting. When using flexible venting, it is required to maintain a 6"
(152mm) rise. See illustrations below for more information.
0.8cm)
IMUM
16
W415-2920 / D-0 / 10.25.24
12"
MINIMUM
REAR EXIT INSTALLATION
6" (152mm)
RISE MINIMUM
6" (152mm)
RISE MINIMUM
FLEX VENTING
16" (406mm)
minimum
40' (12m)
maximum
36" (914mm)
minimum
30"
base of air collar
MINIMUM
MAXIMUM 10FT VENT LENGTH
TOP EXIT INSTALLATION
20" (50.8cm)
MAXIMUM
RIGID VENTING
20" (50.8cm)
MAXIMUM
12"
MINIMUM
30"
MINIMUM
REAR EXIT INSTA