SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone 1 (866) 820-8686 • www.napoleonfi replaces.com • hearth@napoleonproducts.com
$10.00
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
B81NS-1
B81PS-1
INSTALLATION AND
ADD MANUAL TITLE
OPERATION MANUAL
High Definition 81 See Thru
Mineral Rock Burner Assembly
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
IF INSTALLATION + OPERATION, ADD SERIAL
CSA /
INTERTEK
BARCODE LABEL ON THE OWNER'S MANUAL"
LOGO
Product Name / Code
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
FOR INDOOR USE ONLY
NUMBER LABEL HERE
IF SEPARATE MANUALS, ADD "PLACE
ENGLISH
FRENCH
PG. 9
(see price book)
(B81NS-1 illustrated)
W415-0808 / F / 08.30.18

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Napoleon B81NS-1

  • Page 1 INTERTEK BARCODE LABEL ON THE OWNER’S MANUAL” LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleonfi replaces.com • hearth@napoleonproducts.com $10.00 W415-0808 / F / 08.30.18...
  • Page 2: Table Des Matières

    general information general information installation access panel burner assembly bulkheads night light™ installation porcelain base installation burner cover installation rock installation adjustment flame characteristics venturi adjustment replacements overview note: The information throughout this manual is believed to be correct at the time of printing. Wolf Steel Ltd.
  • Page 3: Installation

    installation bulkheads PRIMARY note: BURNER Bulkhead covers need to be removed. DOTS Connect the gas flex lines and the pilot line to the gas bulkheads located under the valve access opening. Be sure to match up the gas manifold marked with a dot with the center bulkhead, also marked with a dot.
  • Page 4: Porcelain Base Installation

    installation porcelain base installation INSTALL IN THE FOLLOWING ORDER: Side porcelain panels or brick panels must be installed prior to porcelain base cover plates. For side porcelain panel installation and for brick panel installation, see leaflets provided with kits. PORCELAIN COVER PLATE Slide the porcelain cover plates through the front opening being careful not to scratch the...
  • Page 5: Rock Installation

    installation rock installation WARNING • Real rocks must not be used in this appliance. Heat will cause them to explode. Position the rocks in front of the center burner Position a few large rocks randomly along the tube. Ensure not to cover burner ports. front.
  • Page 6: Adjustment

    installation 3.0 adjustment flame characteristics It’s important to periodically perform a visual check of the pilot and burner flames. Compare them to the ADD IMAGE illustration provided. If any flames appear abnormal, call a service person. HERE venturi adjustment 36.1 This appliance has an air shutter that has been factory set open according to the chart below: VENTURI...
  • Page 7 installation W415-0808 / F / 08.30.18...
  • Page 8 NAPOLEON CELEBRATING OVER 40 YEARS OF HOME COMFORT PRODUCTS 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Phone: 1-866-820-8686...
  • Page 9 IF SEPARATE MANUALS, ADD “PLACE LOGO BARCODE LABEL ON THE OWNER’S MANUAL” Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 1(866)820-8686 • www.napoleonfoyers.com • hearth@napoleonproducts.com $10.00 W415-0808 / F / 08.30.18...
  • Page 10: Information Générale

    information générale information générale installation panneau d’accès assemblage du brûleur raccords installation de la lumière de veille installation de la plaque de recouvrment en porcelaine installation du couvercle du brûleur installation des roches réglages caractéristiques de la flamme réglage du venturi rechanges vue d’ensemble note:...
  • Page 11: Raccords

    installation raccords note: Les couvercles des raccords doivent être retirés. BRÛLEUR PRIMAIRE Branchez les conduites de gaz flexibles et la POINTS conduite de la veilleuse aux raccords de gaz situés en dessous de l’ouverture d’accès de la soupape. Assurez-vous de faire correspondre le collecteur de gaz marqué...
  • Page 12: Installation De La Plaque De Recouvrment En Porcelaine

    installation installation de la plaque de recouvrment en porcelaine FAITES L’INSTALLATION SELON L’ORDRE SUIVANT: Les panneaux de porcelaine ou de brique latéraux doivent être installés avant les plaques de recouvrement en porcelaine. Pour l’installation du panneau de porcelaine latéral et pour l’installation des panneaux de brique, voir les feuillets fournies avec les ensembles.
  • Page 13: Installation Des Roches

    installation installation des roches AVERTISSEMENT • Ne pas utiliser de vraies roches dans cet appareil. La chaleur les fera exploser. Placez les roches en avant du tube du brûleur Placez quelques grosses roches de façon aléa- central en vous assurant de ne pas couvrir toire le long du devant, en vous assurant de les orifices du brûleur.
  • Page 14: Réglages

    réglage 3.0 réglages caractéristiques de la flamme Il est important d’effectuer périodiquement une inspection visuelle de la flamme de la veilleuse et du ADD IMAGE brûleur. Comparez-les à ces illustrations. Si des flammes paraissent anormales, contactez un HERE technicien de service. réglage du venturi 36.1 L’ouverture du volet d’air a été...
  • Page 15 rechanges W415-0808 / F / 08.30.18...
  • Page 16 NAPOLÉON CÉLÈBRE PLUS DE 40 ANS D’EXISTENCE CONSACRÉS À LA CONCEPTION DE PRODUITS DE CONFORT 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Téléphone: 1-866-820-8686...