This template must be used in conjunction with templates 7.2.1 or 7.2.2, depending on
termination shape (i.e. round, or round and square). See appropriate templates folder.
venting requirements
EN
For optimum fl ame appearance and appliance performance, keep the vent length and number of elbows to a minimum.
The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that
it is unobstructed and undamaged.
Rigid and fl exible venting systems must not be combined. Different venting manufacturer components must not
be combined.
These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal run is 20
feet (6.1m). The maximum allowable vertical vent length is 40 feet (12.2m). The maximum number of vent connections is two
horizontally or three vertically (excluding the appliance and the air terminal connections) when using fl exible venting.
An insulated sleeve has been supplied and must be installed on all rear vent applications for the first
Horizontal runs may have a 0" (0mm) rise per foot/meter however for optimum performance it is recommended that all
24" (61cm).
horizontal runs have a minimum 1/4" (21mm) rise per foot/meter using fl exible venting. For safe and proper operation of the
appliance, follow the venting instructions exactly.
Horizontal runs may have a 0" (0mm) rise per foot/meter however for optimum performance it is recommended
that all horizontal runs have a minimum 1/4" (21mm) rise per foot/meter using flexible venting. For safe and proper
A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwell-
operation of the appliance, follow the venting instructions exactly.
ings and serves both dwellings. Local codes or regulations may require different clearances.
A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single
Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1¼" (31.8mm) air
family dwellings and serves both dwellings. Local codes or regulations may require different clearances.
gap all around between the inner liner and outer liner is required for safe operation.
Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1¼"
If approved for use with a power vent kit, state: "This appliance is certifi ed for use with a power vent kit. Con-
(31.8mm) air gap all around between the inner liner and outer liner is required for safe operation.
tact your local authorized dealer for more information."
This appliance is certified for use with a power vent kit (top vent only). Contact your local authorized dealer for
If not, cover with a white box.
more information.