INSTALLATION INSTRUCTIONS – ELECTRIC DRYER
INSTALLATION INSTRUCTIONS – ELECTRIC DRYER
Power Supply Cord (U.S.A. Only)
A
Electrical Connection Options
If your location has:
4-wire receptacle
(NEMA Type 14R-30R)
3-wire receptacle
(NEMA type 10R-30R)
4-wire direct
3-wire direct
*If local codes do not permit the connection of a cabinet-ground conductor to the neutral wire, go to "Optional 3-wire
connection" section.
And you will be
connecting to:
A UL listed, 120 V/240 V
minimum, 30 A,
dryer power supply cord*
A UL listed, 120 V/240 V
minimum, 30 A,
dryer power supply cord*
A fused disconnect or
circuit breaker box*
A fused disconnect or
circuit breaker box*
3
"
1
2
(89 mm)
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
C
B
E
A. Terminal block cover
B. External ground
conductor screw
3. Install strain relief.
D
A
C. Center terminal block
screw
D. Hold-down screw
E. Neutral ground wire
Go to Section
4-wire connection:
Power supply cord
3-wire connection:
Power supply cord
4-wire connection:
Direct Wire
3-wire connection:
Direct Wire