Must include a shutoff valve:
■
The supply line must be equipped with a manual shutoff
valve installed within 6 ft (1.8 m) of dryer in accordance
with National Fuel Gas Code, ANSI Z223.1. In Canada,
an individual manual shutoff valve must be installed in
accordance with the B149 installation codes CAN/CGA
B149.1 and CAN/CGA B149.2. This valve should be located
in the same room as the dryer. It should be in a location that
allows ease of opening and closing. Do not block access to
shutoff valve. The valve is for turning on or shutting off gas
to the dryer.
A
A. Gas supply line
B. Shutoff valve in "open" position
C. To dryer
D. NPT 1/8" minimum plugged tapping
Installed in a confined area:
■
If the dryer is installed in a confined area such as a
bathroom or closet, provision must be made for enough
air for combustion and ventilation. Check governing codes
and ordinances or refer to the "Recessed Area and Closet
Installation Instructions" in the "Location Requirements"
section.
Connect Vent
1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet
on the dryer. If connecting to existing vent, make sure the
vent is clean. The dryer vent must fit over the dryer exhaust
outlet and inside the exhaust hood. Make sure the vent is
secured to exhaust hood with a 4" (102 mm) clamp.
2. Using two or more people, move dryer to desired installation
location. Do not crush or kink vent, and remove any excess
flexible vent to improve airflow. Make sure dryer is level.
3. Check to be sure there are no kinks in the flexible gas line.
14
B
D C
Complete Installation
1. With dryer in final position, place level on top of the dryer, first
side to side; then front to back. If the dryer is not level, adjust
the legs of the dryer up or down until the dryer is level.
2. Check the electrical requirements. Be sure that you have the
correct electrical supply and the recommended grounding
method. See "Electrical Requirements."
3. Check that all parts are now installed. If there is an extra part,
go back through the steps.
4. Check that you have all of your tools.
5. Dispose of/recycle all packaging materials.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 or 4 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
6. Plug into a grounded outlet, or connect power.
7. Check dryer operation:
Insert coins. Select a cycle. Using the WHITES & COLORS
cycle, let the dryer run for at least 5 minutes. Dryer will stop
when time is used up.
Note: Dryer door must be closed for dryer to operate.
When door is open, dryer stops, but timer continues to run.
To restart dryer, close door and reselect a cycle.
8. If the burner does not ignite and there is no heat inside the
dryer, shut off dryer for 5 minutes. Check that all gas supply
valves are in the "ON" position and that the electrical cord is
plugged in Repeat 5 minutes test.
9. If drying time is too long, make sure that the lint screen is
clean and that there are no obstructions to airflow in the dryer
vent system.