4 Programmation
4.4.6 5-** E/S Digitale
N° de
Description du paramètre
par.
5-0* Mode E/S digitales
5-00
Mode E/S digital
5-01
Mode born.27
5-02
Mode born.29
5-1* Entrées digitales
5-10
E.digit.born.18
5-11
E.digit.born.19
5-12
E.digit.born.27
5-13
E.digit.born.29
4
5-14
E.digit.born.32
5-15
E.digit.born.33
5-16
E.digit.born. X30/2
5-17
E.digit.born. X30/3
5-18
E.digit.born. X30/4
5-19
Terminal 37 Safe Stop
5-20
Terminal X46/1 Digital Input
5-21
Terminal X46/3 Digital Input
5-22
Terminal X46/5 Digital Input
5-23
Terminal X46/7 Digital Input
5-24
Terminal X46/9 Digital Input
5-25
Terminal X46/11 Digital Input
5-26
Terminal X46/13 Digital Input
5-3* Sorties digitales
5-30
S.digit.born.27
5-31
S.digit.born.29
5-32
S.digit.born. X30/6
5-33
S.digit.born. X30/7
5-4* Relais
5-40
Fonction relais
5-41
Relais, retard ON
5-42
Relais , retard OFF
5-5* Entrée impulsions
5-50
F.bas born.29
5-51
F.haute born.29
5-52
Val.ret./Réf.bas.born.29
5-53
Val.ret./Réf.haut.born.29
5-54
Tps filtre pulses/29
5-55
F.bas born.33
5-56
F.haute born.33
5-57
Val.ret./Réf.bas.born.33
5-58
Val.ret./Réf.haut.born.33
5-59
Tps filtre pulses/33
5-6* Sortie impulsions
5-60
Fréq.puls./S.born.27
5-62
Fréq. max. sortie impulsions 27
5-63
Fréq.puls./S.born.29
5-65
Fréq. max. sortie impulsions 29
5-66
Fréq.puls./S.born.X30/6
5-68
Fréq. max. sortie impulsions X30/6
5-7* Entrée cod. 24V
5-70
Pts/tr cod.born.32 33
5-71
Sens cod.born.32 33
5-9* Contrôle par bus
5-90
Ctrl bus sortie dig.
5-93
Ctrl par bus sortie impulsions 27
5-94
Tempo. prédéfinie sortie impulsions 27
5-95
Ctrl par bus sortie impulsions 29
5-96
Tempo. prédéfinie sortie impulsions 29
5-97
Pulse Out #X30/6 Bus Control
5-98
Pulse Out #X30/6 Timeout Preset
74
Valeur par défaut
[0] PNP
All set-ups
[0] Entrée
All set-ups
[0] Entrée
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
[1] Safe Stop Alarm
[0] Inactif
All set-ups
[0] Inactif
All set-ups
[0] Inactif
All set-ups
[0] Inactif
All set-ups
[0] Inactif
All set-ups
[0] Inactif
All set-ups
[0] Inactif
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
0.01 s
All set-ups
0.01 s
All set-ups
100 Hz
All set-ups
100 Hz
All set-ups
0.000 ReferenceFeedbackUnit
All set-ups
ExpressionLimit
All set-ups
100 ms
All set-ups
100 Hz
All set-ups
100 Hz
All set-ups
0.000 ReferenceFeedbackUnit
All set-ups
ExpressionLimit
All set-ups
100 ms
All set-ups
null
All set-ups
ExpressionLimit
All set-ups
null
All set-ups
ExpressionLimit
All set-ups
null
All set-ups
ExpressionLimit
All set-ups
1024 N/A
All set-ups
[0] Sens horaire
All set-ups
0 N/A
All set-ups
0.00 %
All set-ups
0.00 %
0.00 %
All set-ups
0.00 %
0.00 %
All set-ups
0.00 %
MG.35.D1.04
Manuel d'utilisation du 3G3DV
4 set-ups
Changement
Indice
pendant le fonc-
de conver-
tionnement
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
TRUE
TRUE
1 set-up
TRUE
TRUE
1 set-up
TRUE
TRUE
1 set-up
TRUE
Type
sion
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
0
Uint32
-
Uint8
0
Uint32
-
Uint8
0
Uint32
0
Uint16
-
Uint8
0
Uint32
-2
N2
-2
Uint16
-2
N2
-2
Uint16
-2
N2
-2
Uint16