Tableau 8 Erreurs de Storage Management Provider (suite)
Code d'erreur
Message d'erreur
0x21005061
Failed to remove partition data from the logical
drive. You must manually clear the disk or delete
the partition. Otherwise, subsequent volume
creation requests might fail.
0x20005062
The format of the specified RAID level is invalid.
Valid RAID levels are RAID 0, RAID 1, RAID 10,
RAID 5, RAID 6, RAID 50, RAID 60, RAID 10
(ADM), RAID 50 (2), RAID 50 (3), RAID 50 (4),
RAID 50 (5), RAID 1 (ADM), RAID 60 (2), RAID
60 (3), RAID 60 (4), RAID 60 (5).
0x20005063
The format of the specified RAID level is invalid.
Valid RAID levels are RAID 0, RAID 1, RAID 10,
RAID 5, RAID 6.
0x23005064
The length of the virtual disk friendly name exceeds
the maximum supported length.
0x24005065
Failed to get the pool from the logical drive.
0x25005068
The virtual disk could not complete the operation
because its health or operational status does not
permit it.
0x24005069
Enclosure not found in cache.
0x2500506A
Failed to update enclosure in cache.
0x2400506B
Failed to get the enclosure for the physical disk.
0x2400506C
Failed to get WMI class names to subscribe.
0x2100506D
SMP assembly file not found.
0x2700506E
The registry key
HKLM\HARDWARE\Description\System\BIOS
was not found.
0x2700506F
The registry key
HKLM\HARDWARE\Description\System\BIOS\
SystemProductName
was not found.
0x21005070
SmartArray.dll file not found.
0x21005071
Raptor.dll file not found.
0x21005072
Failed to get the library name to load.
0x25005073
Failed to release the lock.
0x24005074
Failed to create the mutex.
0x24005075
Failed to get the proxy to the controller library.
0x25005076
The resiliency setting does not match the pool's
resiliency setting.
0x25005077
The operation was successful but the storage
provider cache is out of date. You must update the
storage provider cache before proceeding further.
Action recommandée
Réinstallez HP Storage Management Provider.
Réitérez l'opération.
Redémarrez HP Storage Management Service.
Mettez à jour le cache du fournisseur de gestion de
stockage en appelant la commande Windows PowerShell
Update-StorageProviderCache.
Redémarrez HP Storage Management Service.
Mettez à jour le cache du fournisseur de gestion de
stockage en appelant la commande Windows PowerShell
Update-StorageProviderCache.
Redémarrez HP Storage Management Service.
Redémarrez HP Storage Management Service.
Réinstallez HP Storage Management Provider.
Le système est dans un état non valide. Contactez
l'assistance HP.
Le système est dans un état non valide. Contactez
l'assistance HP.
Réinstallez HP Storage Management Provider.
Réinstallez HP Storage Management Provider.
Réinstallez HP Storage Management Provider.
Mettez à jour le cache du fournisseur de gestion de
stockage en appelant la commande Windows PowerShell
Update-StorageProviderCache.
Redémarrez HP Storage Management Service.
Redémarrez HP Storage Management Service.
Mettez à jour le cache du fournisseur de gestion de
stockage en appelant la commande Windows PowerShell
Update-StorageProviderCache.
Mettez à jour le cache du fournisseur de gestion de
stockage en appelant la commande Windows PowerShell
Update-StorageProviderCache.
Codes d'erreur 123