Max PowerLite HA55SF2/18 Manuel D'instructions page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Never carry out nail driving while pressing the nail-removing
lever 1, since nails will become jammed and may cause
equipment breakdown. This equipment incorporates an emp-
ty-firing prevention device so that the contact arm will not
move when there is no nail loaded. In order to confirm the op-
eration of the safety equipment or to check the movement of
the contact arm, carry out the operations while pressing the
nail-removing lever 1 to release the empty-firing prevention
device.
• Confirm these operations when there are no nails loaded.
HOW TO MOUNT CONTACT TIP
WARNING
ALWAYS disconnect air supply before setting the contact tip. Set
the contact tip on the top of the contact arm, when driving nails to
a soft material.
1
Disconnect the air supply. Remove the nails from inside the
magazine.
(Fig.10) While pressing the click lever 1, pull out the slider
2
2.
(Fig. 11, Fig. 12) Insert the hex wrench 1 attached to the
3
slider into the slider hole 2 to remove the contact tip 3.
(Fig. 13) Mount the contact tip 1 to the contact arm end 2.
4
Mount the contact tip so that the projection 3 of the contact
tip faces in the direction shown in the figure.
HOW TO STORE CONTACT TIP
(Fig. 14) Insert the contact tip 1 into the slider's projection
1
2. Insert the contact tip so that the projection 3 faces in
the direction shown in the figure.
(Fig. 15) Insert the lower portion of the contact tip 1 in the
2
direction shown by the arrow (→).
3
(Fig. 16) Confirm that the contact tip is caught by the slider
projection 1.
REMOVING JAMMED NAILS
WARNING
ALWAYS disconnect the air supply.
Wear gloves when removing jams; do not use bare hands
Confirm that you have removed all nails from nose of tool
before reconnecting to air supply.
1
Disconnect the air supply. Remove the nails from inside the
magazine.
(Fig.17) Pull out the hex wrench 1 stored in the magazine
2
rear part.
(Fig.18) Loosen the screws 1 that fix the contact nose A
3
2, and remove it.
4
Remove the jammed nail.
(Fig.19) Mount the contact nose A 1, and securely tighten
5
the screws 2.
CONCERNING THE HOOK (Fig.20)
It is possible to change the hook width by sliding the hook 1.
Before storing the equipment in the carrying case, narrow the
width of the hook 1.
METHOD OF CHANGING THE HOOK DIRECTION
It is also possible to mount the hook on the right hand side of the
main unit.
(Fig.21) Remove the screw 1 using a hex wrench (4mm)
1
2.
(Fig.22) Mount the hook 1 on the right hand side of the
2
main unit, and reinsert and tighten the screw 2.
HOW TO USE AIR DUSTER
WARNING
Never point the injection outlet or the air duster blow off
vent toward a person.
Always lock the trigger before using the air duster.
Do not disconnect the air hose with the air duster button
pressed.
Aim the air blow off vent and press the air duster button 1.
• Air flow volume control function is provided for the
HA-55SF2(D) air duster. Control air flow volume by pressing
the air duster button 1.
Guideline of Air Duster Air Flow
Air-Flow Control Button Explanation
1 Press lightly.
2 Press halfway.
3 Press fully.
4
Air Flow
Low air flow
Medium air flow
High air flow

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Powerlite nf255sf2/18

Table des Matières