When the window detection function is enabled, if the product
detects a temperature drop of 5–10°C within 10 minutes, it will stop
heating and enter standby mode within 30 minutes.
To restart the product, press the device on/off button (a) "
the device or remote control.
To disable the window detection function, press the open window
detection on/off button (i) "
turn off, and the product will revert to its previous operating state.
e.g. If the ambient temperature is below 23°C and the window
detection function is enabled with a set temperature of 23°C, the
display will appear as shown below.
3) Interaction with weekly timer function
If both the window detection and weekly timer functions are
enabled, the product will not start during the off-periods set by the
weekly timer.
If the product is already operating during a weekly timer period, it
will operate based on the temperature set for the window detection
function. (See the picture below)
EN
" again. The "
" on