LCD Panel
LCD Panel / LCD-Bildschirm / Panneau LCD / Panel LCD / Painel de LCD / LCD-paneel
/ Pannello LCD / Panel LCD / LCD panel / LCD-panel / Panou cu LCD / LCD панел /
LCD-panel / Πάνελ LCD / LCD-paneel / LCD-paneeli / LCD ploča / LCD panel / LCD
skydas /LCD panelis / LCD Panel / LCD plošča / LCD Panel / Painel LCD / OLED ‫لوحة‬
• Inverter
Timely output power
Daily generated enengy
Left capacity of battery energy
* Please refer to the actual product for the color of the LCD screen. The screen displayed
in the manual is for aesthetic purpose.
In normal state, the "Power", "Today" and "Battery" information will be displayed. You can
press the keys to switch information.
In error state, the fault message and error code will be displayed, please refer to
corresponding solutions in the user manual.
LED indicator
Operating
Error
Battery
170
Status or error information
Power
Today
Battery
Operating indicator light
Battery indicator light
Error indicator light
Status
Solid blue
Blue blinking
Light off
Solid red
Light off
Solid green
Green blinking
Light off
LCD screen
0W
0.0KWh
80%
Normal
ESC Up Down Enter
Definition
The inverter is in normal status or
EPS (Off-grid) mode.
The inverter is in waiting,checking
status or the system switch is off.
The inverter is in fault status.
The inverter is in a fault state.
The inverter is in norml status.
The battery communication is in
normal status and working normally.
The battery communication is in
normal status and in an idle status.
The inverter is in fault status.