COMMON FAULTS AND SOLUTIONS
Fault symptom
Motor does not work
The motor works but fails
to raise the lift
The motor works but can
raise the unloaded lift only
Lowering speed of the lift is
slow
Lifting speed of the lift is
slow or oil overflows the oil
cap
Fault causes
The fusible core is burnt out
The motor voltage is improper
Motor is burnt out
The motor rotates reversely
Pump is damage or leaks
inside
Oil level is low
Operating voltage of motor is
low
Gear pump may be damaged
Pressure of relief valve is
adjusted insufficiently
Lift is overloaded
There are foreign matters in
the lowering solenoid valve
Opening of lowering throttle
valve is too small
The oil contains air
Troubleshooting methods
Replace the fusible core
Supply proper voltage to the
motor
Replace the motor
Change the motor by
changing the motor lead
Inspect the hydraulic circuit
Add oil to the hydraulic tank
Supply proper voltage to the
motor
Inspect the pump pressure
Adjust the pressure of relief
valve
Inspect the weight of vehicle
Clean the lowering solenoid
valve
Rotate the throttle valve
counterclockwise to
appropriate position
The oil shall not be mixed with
air

Publicité