PONT ELEVATEUR 4 COLONNES
PE 4101T
CHEMIN PLAT OSCILLANT 400V 5T
Tension
Power
380V
3KW
220V
3KW
380V
2.2KW
220V
2.2KW
Note: Please use the power wires with minimum size of 2.5 mm
interface U, V and W to the motor interface X, Y and Z.
Note: Connect the safety device test wire as the colour of the cable: red&blue
8. The same applies to the others.
9. Activate all detection switches and set mode to "Work "
10. Adjustment made.
Operating
Starting current
current
21A-35A
8.5A
60A
21A-25A
18A-30A
7.5A
60A
20A-22A
6. Loosen the detection switch screw on the
corresponding column cylinder.
7. Continue to press the down button while
moving the detection switch position on the
cylinder until the detection switch lights up;
the detection switch position has now been set.
Tighten the detection switch screws.
Wire size
Air switch
≥ 2,5 mm
2
≥ 4 mm
2
≥ 2,5 mm
2
≥ 4 mm
2
to connect the power supply
2
Applicable to
C63
Scissor lift
C63
Scissor lift
Two posts,
C63
the gantry, four
posts
Two posts,
C63
the gantry, four
posts