Electrical installation diagram
How do I adjust the position of the detector in the event of a malfunction of the protective sensor?
This product is equipped with a safety sensor as standard. If one of the pillars of the four-column
elevator cannot open the safety device, the elevator will stop lowering.When the lowering button
cannot be pressed, it is possible that the position of the safety sensor is incorrectly set, and the
following adjustments need to be made:
1. Check that the air supply pressure is normal.
2. Deactivate the four detection switches and check that they can descend.
3. If step 2 cannot be lowered, gradually turn all four switches to ON
4. If it is not possible to press the lowering button, the column detection
switch corresponding to this switch must be adjusted.
5. Set switch to "TEST" position.

Publicité