STANDING PILOT -LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
A. This appliance is equipped with an ignition device which
automatically lights the pilot.
Do not try to light the pilot by hand.
B. BEFORE OPERATING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting (if applicable).
3. Turn off all electric power to the appliance.
4. Remove control access panel (lower front panel).
5. Turn gas control knob clockwise
6. Wait ten (10) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas, STOP!
Follow "B" in the safety information above. If you don't
smell gas, go to the next step.
7. Remove the pilot access cover located on the combus-
tion chamber.
8. Find pilot - follow metal tube from gas control. The
pilot is located between
the two burner tubes
behind the pilot access
cover.
1. Set the thermostat to lowest setting (if applicable).
2. Turn off all electric power to appliance if service is to
be performed .
3. Remove control access panel (lower front panel).
32190-3-0514
causing property damage, personal injury or loss of life.
OPERATING INSTRUCTIONS
to "OFF."
TO TURN OFF GAS TO APPLIANCE
• If you cannot reach your gas supplier, call the
fire department.
C. Use only your hand to slide the gas control knob.
Never use tools. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of
the control system and any gas control which has
been under water.
9. Turn gas control knob counterclockwise
"PILOT."
10. Push and hold red reset button down completely and
repeatedly push the ignitor button until the pilot burner
is lit. Pilot may also be lit with a match. Continue to
hold the red reset button down for about one (1) minute
after the pilot is lit. Release button and it will pop back
up. Pilot should remain lit. If it goes out, repeat steps
5 through 10.
• If button does not pop up when released, stop and
immediately call a qualified service technician or
gas supplier.
• If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
11. Replace pilot access cover.
12. Turn gas control knob counterclockwise
to "ON."
13. Replace control access panel (lower front panel).
14. Turn on all electric power to the appliance.
15. Set thermostat to desired setting (if applicable).
4. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
5. Replace control access panel (lower front panel).
to