Size
Usage limitations
For swing gates, installing an electric lock is always recommended. This is to ensure the leaves close reliably and to protect the gearmotor parts. It is also
recommended for irreversible gearmotors – and is mandatory where the leaves are more than 2.5 m in length. For reversible gearmotors, electric locks are required
to ensure the leaves close. The installer is responsible for installing an electric lock, taking into account the size and type of leaf (e.g. panelled) and the installation
area (e.g. windy location).
MODELS
Gate-leaf length (m)
Leaf weight (kg)
Technical data
MODELS
Power supply (V - 50/60 Hz)
Motor power supply (V)
Power (W)
Capacitor (μF)
Current draw (A)
Operating temperature (°C)
Torque (Nm)
Opening time at 90° (s)
Cycles/hour
Motor thermal protection (°C)
Protection rating (IP)
Storage temperature (°C)*
Average life (cycles)**
Weight (kg)
(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a very high or very low temperature.
(**) The average product life specified should be understood purely as an indicative estimate. It applies to normal usage conditions and where the product has been
installed and maintained in compliance with the instructions provided in the CAME technical manual. The average product life is also affected, including significantly,
by other variables such as, but not limited to, climatic and environmental conditions. The average product life should not be confused with the product warranty.
Cable types and minimum thicknesses
Cable length (m)
Motor power supply 230 V AC
When operating at 230 V and outdoors, use H05RN-F cables compliant with 60245 IEC 57 (IEC); when indoors, use H05VV-F cables compliant with 60227 IEC 53
(IEC). For power supplies up to 48 V, use FROR 20-22 II cables compliant with standard EN 50267-2-1 (CEI).
If the cable lengths differ from those specified in the table, define the cable cross-sections according to the actual power draw of the connected devices and in
line with regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, recalculate the values in the table according to the actual power draw and distances. For information on
connecting products not covered in this manual, please see the documentation accompanying the products themselves.
To connect the encoder, use a FROR 300/500 V shielded cable (3 x 0.5 mm²).
586
FROG-PM4
5.5
4.5
3.5
700
900
1100
up to 20
4G x 1.5 mm2
644
94
426
2.5
7
1400
550
FROG-PM4
230 AC
230 AC
500
16
2,1
-20 ÷ +55
800
30
10
150
67
-20 ÷ +70
150.000
38
FROG-PM6
6
5
4
650
800
1000
FROG-PM6
230 AC
230 AC
500
16
2,1
-20 ÷ +55
800
45
6
150
67
-20 ÷ +70
150.000
38
from 20 to 30
4G x 2.5 mm2