GENERAL PRECAUTIONS FOR INSTALLERS
Important safety instructions.
Please follow all of these instructions. Improper installation may cause serious bodily harm.
Before continuing, please also read the general precautions for users.
Only use this product for its intended purpose. Any other use is hazardous. • The manufacturer cannot be held liable for any
damage caused by improper, unreasonable or erroneous use. • This product is defined by the Machinery Directive (2006/42/EC)
as partly completed machinery. • Partly completed machinery means an assembly which is almost machinery but which cannot
in itself perform a specific application. • Partly completed machinery is only intended to be incorporated into or assembled with
other machinery or other partly completed machinery or equipment thereby forming machinery to which the Machinery Directive
(2006/42/EC) applies. • The final installation must comply with the Machinery Directive (2006/42/EC) and the European reference
standards in force. • The manufacturer declines any liability for using non-original products, which would also void the warranty. •
All operations indicated in this manual must be carried out exclusively by skilled and qualified personnel and in full compliance with
the regulations in force. • The device must be installed, wired, connected and tested according to good professional practice, in
compliance with the standards and laws in force. • All the components (e.g. actuators, photocells and sensitive edges) needed for
the final installation to comply with the Machinery Directive (2006/42/EC) and with the reference harmonised technical standards
are specified in the general CAME product catalogue or on the website www.came.com. • Make sure the mains power supply is
disconnected during all installation procedures. • Check that the temperature ranges given are suitable for the installation site.
• Do not install the operator on surfaces that could yield and bend. If necessary, add suitable reinforcements to the anchoring
points. • Make sure that no direct jets of water can wet the product at the installation site (sprinklers, water cleaners, etc.). •
Make sure you have set up a suitable dual-pole cut-off device along the power supply that is compliant with the installation rules.
It should completely cut off the power supply according to category III surcharge conditions. • Demarcate the entire site properly
to prevent unauthorised personnel from entering, especially minors. • In case of manual handling, have one person for every 20
kg that needs hoisting; for non-manual handling, use proper hoisting equipment in safe conditions. • Use suitable protection to
prevent any mechanical hazards due to persons loitering within the operating range of the operator. • The electrical cables must
pass through special pipes, ducts and cable glands in order to guarantee adequate protection against mechanical damage. • The
electrical cables must not touch any parts that may overheat during use (such as the motor and transformer). • Before installation,
check that the guided part is in good mechanical condition, and that it opens and closes correctly. • The product cannot be used
to automate any guided part that includes a pedestrian gate, unless it can only be enabled when the pedestrian gate is secured. •
Make sure that nobody can become trapped between the guided and fixed parts, when the guided part is set in motion. • All fixed
controls must be clearly visible after installation, in a position that allows the guided part to be directly visible, but far away from
moving parts. In the case of a hold-to-run control, this must be installed at a minimum height of 1.5 m from the ground and must
not be accessible to the public. • Where operated with a hold-to-run control, install a STOP button to disconnect the main power
supply to the operator, to block movement of the guided part.