Télécharger Imprimer la page

OBI Maraca Notice Originale page 42

Publicité

GB
Note: The installation instructions are
designed for use by a qualified technician
who has thorough knowledge of the fol-
lowing areas:
• Occupational safety, operational
safety and accident prevention regula-
tions
• Working with ladders and scaffolding
• Handling and transport of long, heavy
components
• Working with tools and machines
• Installation of fixing materials
– Evaluation of building structure (If
you have any questions, consult
your dealer.)
• Initial commissioning and operation of
the product
If one of this qualifications are not availa-
ble, then an installation company with
expertise in this field should be commis-
sioned to carry out the work.
Note: Two persons must be present when
installing the awning. A ladder will be nec-
essary. The awning should be attached
precisely horizontally to guarantee a
smooth extension and retraction of the
awning.
Note: Remember, the wall bracket must
be installed approximately 10 cm from the
end of the awning.
DANGER! Risk of injury! Never position
the selected fastening material in mortar
joints. Please observe specified edge dis-
tances. Make sure that there is enough
load-bearing capacity (masonry/wall
material) above the fastening holes to
ensure that there is no risk of any damage
to the masonry or wall material caused by
the forces acting on an extended awning.
DANGER! Risk of injury! In case of low
installation, please ensure that there are
no objects within the swivel range.
DANGER! Risk of injury! Wind can sig-
nificantly impact an awning. An improp-
erly mounted awning may break loose
from its underpinnings and cause serious
injury.
WARNING! Danger of falling! Maintain
a safe stance during the installation pro-
cess.
Determine the height at which the awning is to be fas-
tened to the wall. If the awning is to be installed above
a door, the clearance above the door must be at least
20 cm. Please also observe the inclination angle of
the awning. The minimum inclination angle of the
cloth to the water drainage in case of rain must be
14°. After installation, the angle can be easily
changed as required. The front drop rod (front profile)
should have a clearance height of at least 2.5 m when
extended.
42
Pls make sure the heigth before installation according
to the height of front bar (H) and the angle of sunshine
(α). After open the awning, the height must up to
human so it can protect your head from hitting the
awning.
Note: Moving parts of the drive must be
installed higher than 2.5m above the floor
or other level that could provide access to
it.
► P. 5, fig. 1
L = 2,5 m
– α = 80°
C = H + 450 mm
– α = 75°
C = H + 650 mm
– α = 70°
C = H + 850 mm
– α = 65°
C = H + 1050 mm
L = 2,0 m
– α = 80°
C = H + 350 mm
– α = 75°
C = H + 520 mm
– α = 70°
C = H + 690 mm
– α = 65°
C = H + 850 mm
► P. 5, fig. 3
– Transfer the dimensions to the appropriate posi-
tion on the wall.
647309
► P. 5, fig. 2
– X1 = 2410 mm
– Y1 = 90 mm
– Y2 = 50 mm
– Z = 220 mm
647310
► P. 5, fig. 3
– X1 = 2870 mm
– X2 = 1430 mm
– Y1 = 90 mm
– Y2 = 50 mm
– Z = 490 mm
– Align the dimensions for other brackets using a
spirit level.
► P. 6, fig. 4
– Drill at the marked positions. Use a drill with 12
mm diameter and drill slightly deeper than the
length of the wall anchor.
► P. 6, fig. 5
– Insert the wall anchors into the drilled holes.
– Screw connect the brackets with the wall anchors.
– wall installation: ► P. 6, fig. 6
– ceiling installation: ► P. 6, fig. 7
• Installation sequence: Bracket, washers, locking
ring, nuts.
► P. 6, fig. 8
– Insert the awning into the brackets (two people
are needed). For this, insert the awning's support-
ing tube into the brackets, place the nut on from
the top, screw in the bolt and washer from under-
neath, and tighten.

Publicité

loading

Ce manuel est également adapté pour:

647309647310