3. Technical data

Product specific data
Process gases
Plasma gas:
Argon, Argon/Helium, Helium
Protective gas: Inert or Inert/active gas mixtures
Main arc
Type of voltage:
Polarity of the tungsten electrode:
Polarity of the work piece:
Working voltage:
Welding current:
Pilot-/auxiliary arc
Type of voltage:
Polarity of the tungsten electrode:
Polarity of the work piece:
Working voltage:
Lenght of cable assembly, standard
Tungsten electrode:
Electrical control device
Breaking capacity of potentiometer:
Breaking voltage of key button:
Breaking current of key button:
Breaking capacity of key button:
Data concerning torch cooling
Type:
Type of cooling:
max. supply temperature:
min. flow rate:
Flow pressure:
Conductance of coolant:

General data

Ambient Temperature:
– when welding:
– during shipment and storage:
Relative air humidity:
0.5 – 1.5 l/min
4 – 12 l/min
Direct current
cathodic (–)
anodic (+)
10 – 40 Volt
3 – 100 Ampere at 100 % ED
With standard wear-and-tear parts.
Direct current
cathodic (–)
anodic (+)
2 – 10 Ampere
4,0 m and 8,0 m
WS-2 (turquoise), lenght = 57 mm
dia. 1.0/1.6/2.4/3.2 mm
linear 1 W at 40 °C
0.02 – 41 V (D.C. and A.C.)
0.01 – 100 mA
max. 1 W (resistive load)
ABIPLAS
®
WELD 100W
liquid-cooled
45°C
0.5 l/min
min. 2 bar, max. 4 bar
max. ≤ 30 µS/cm
– 10 °C to + 40 °C
– 25 °C to + 55 °C
up to 90% at a temp. of 20 °C