2.5 Emergency information

3 Product description

3.1 Technical data

Welding
Transport and storage
Relative humidity
Tab. 1
Ambient conditions
®
Type ABIPLAS
WELD
Type of use
DC polarity of the electrodes
Voltage rating
Max. arc inflammability and stabilisation
voltage
Breakdown voltage 50 Hz
Protection type of the device connections
(EN 60529)
Type of cooling
Tab. 2
Product-specific torch data (EN 60974-7)
BAL.0311 • 2018-02-05
In the event of an emergency, immediately disconnect the following supplies:
• Electrical power supply
• Coolant supply
• Gas supply
Further measures can be found in the power source operating instructions or
the documents for further peripheral devices.
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and
material property.
• Use the device according to its designated use only.
• Do not convert or modify the device to enhance its performance without
authorisation.
• The device must only be used by qualified personnel (in Germany, see
TRBS 1203).
3 Product description
−10 °C to +40 °C
−25 °C to +55 °C
Up to 90 % at 20 °C
250 MT
Automatic
Usually negative
Peak value of 141 V
7 kV
IP2X
Liquid
EN - 5