Default
Drying temperature
Firing temperature
Cooling temperature
Heating speed
Burning time
Cooling rate
°C
Menu
Selection
set 1
1 x set button
set 2
2 x set button
set 3
3 x set button
R, SGR
4 x set button
MA.t
5 x set button
FAL. GR
6 x set button
Set 2
Set1
Function
Up to this temperature the furnace heats at the
set speed (menu - [GrAd] -). heating up. When
the drying temperature is reached the furnace
heats up at the maximum speed up to the firing
temperature. If - [20] - is entered, this function
is switched off and the furnace heats up to the
firing temperature. [20] - this function is switched
off and the furnace heats up directly with maxi-
mum speed up to the firing temperature
The furnace heats up to this temperature
Up to this temperature, the furnace cools at the
set speed (menu – [FAL.GR] –). When the coo-
ling temperature is reached the controller
switches to – [StoP] –. The actual temperature
in the furnace continues to be displayed. When
the firing temp temperature is equal to the
cooling temperature this function is switched
off. The controller then switches off after the
firing time has elapsed [StoP]
Input of the temperature increase per hour.
Example: When entering - [100] the oven heats
up 100° per hour until the drying temp.
temperature (menu - [Set 1] -) is reached
Holding time of firing temperature (Menu -
[Set 2] -) Input format: hh.mm (hours / minutes)
Input of the temperature cooling per hour.
Example: When entering - [50] the furnace
cools down 50° per hour until the cooling tem-
perature is reached (menu - [Set 3] -) is reached.
Ma.t
Set 3
t