Translation of the original instructions
REPLACING THE INSIDE GUARD SCREEN (REF. 043596)
01
Remove the guard and the outer guard
screen
REPLACEMENT OF SIDE GUARDS (REF. 075603)
01
Remove the protection
BATTERY REPLACEMENT
01
Remove the protection and the exterior
guard screen
- recycle used lithium batteries. Batteries are considered hazardous waste in Europe.
- do not throw in the trash, only place in the collection bins for used batteries.
SYMPTOMS AND SOLUTIONS
The optoelectronic filter does not work.
Filter stays dark after the weld arc is extinguished or when no arc is
present.
Uncontrolled and sparkling switching: The filter lightens and darkens
when welding.
Side of the filter is lighter than the center of viewing area.
GYSMATIC 2.0 CL TRUE COLOR XXL
02
Press the 2 clips holding the filter in
place
02
Press the 2 clips holding the side filter
in place
02
Press the 2 clips that hold the filter
Activate the solar charge by exposing the cell to the light between 20 to 30 minutes - Check and
change battery if necessary.
Check that you have selected the adjustment range 4-8 or 8-12 using the "MODE" button.
Check and clean detectors if needed.
Adjust sensitivity knob to the lower position (level 1). If the welding place is extremely bright, it
is recommended to reduce light level.
Check arc sensors are not blocked from direct access to the arc light. Set the sensitivity level to
5.
It is a natural feature of LCD's, this symptom is not dangerous for the eyes. However for a
maximum comfort, try to keep an view angle at around 90°.
03
Push the filter slightly outwards
03
Push the side filter upwards
03
Lightly push the filter towards
the outside
10
EN
04
a
a
The inner rear screen can be removed
by slightly lifting the sides (a). When
changing the screen, remember to
remove the protective film first. This
film cannot be removed when the face
shield is already in position in the mask.
04
Replace the side filter
04
Change the 2 CR2032 batteries. It is
recommended to replace the batteries
once a year.