Télécharger Imprimer la page
Delta TECK II Flush 061132A Installation
Delta TECK II Flush 061132A Installation

Delta TECK II Flush 061132A Installation

Électronique exposée robinet de chasse d'eau

Publicité

Liens rapides

ElectronicExposed
TECK
II Flush Valve
®
Button & Board
Repair Kit
INSTALLATION:
• If hardwire, disconnect power.
• Remove the chrome cover by taking out the two hold-down adaptor screws.
• You will now see the clear electronic compartment with a grey cover.
• Remove the two brass hold-down adaptors. NOTE: Left-hand threads! See Figure 1.
• Remove grey cover.
• Disconnect solenoid wires from board.
• Disconnect board from power source in clear case (either battery case or hardwire converter).
• Remove board and button from clear case.
• Insert new board into slots in clear case.
• Connect solenoid wires (black → black and red → red).
• Connect board to power source in clear case (either battery case or hardwire converter).
• Centre new button on circular protrusion on board. See Figure 2.
• Route solenoid wires from board to beside button and ensure that it will not be pinched once
grey case is put back on the clear case (cut-out in underside of grey case for solenoid wires)
See Figure 3.
• Place the hold-down adaptor screws into the compartment holes and tighten down.
NOTE: Left-hand threads!
• Replace the chrome cover and two cover screws - do not overtighten cover screws.
• If hardwire, reconnect power.
Upon power up - a sequence of descending and ascending red lights will signify that the valve is in operation mode.
Once in operation mode, if factory settings are preferred, no further action is required and the valve installation is complete.
Factory pre-set functions are:
Refer to the "Making Adjustments" section of the previously provided M&I.
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as items
relating to ongoing maintenance suggestions and procedures are included.
3
061132A - Water Closet
061133A - Urinal
(includes Electronic Board & Button)
Fig. 2
WC sensing distance of 30", 24 hour flush is off and flush delay is 3 to 6 seconds.
Urinal sensing distance of 28", 24 hour flush is on and a 0 to 3 second flush delay.
w w w . s p e c s e l e c t . c o m
Left-hand
Threads
Fig. 3
Fig. 1
205625 Rev. B

Publicité

loading

Sommaire des Matières pour Delta TECK II Flush 061132A

  • Page 1 ElectronicExposed TECK II Flush Valve ® Button & Board Repair Kit 061132A - Water Closet 061133A - Urinal (includes Electronic Board & Button) INSTALLATION: • If hardwire, disconnect power. • Remove the chrome cover by taking out the two hold-down adaptor screws. •...
  • Page 2 Électronique exposée Robinet de chasse d’eau TECK II Bouton et Carte ® Trousse de réparation 061132A - Toilette 061133A - Urinoir (comprennent une carte électronique et un bouton) INSTALLATION : • Si câblé, débranchez l’alimentation électrique. • Enlevez le couvercle en chrome en retirant les deux vis de retenue de l’adaptateur. •...

Ce manuel est également adapté pour:

Teck ii flush 061133a