NOTE: For optimum performance of this product, we
recommend a system pressure between 25 and 80
PSI static. This product will operate up to a maximum
of 125 PSI static per ANSI and CSA requirements.
However, we do not recommend pressure above
80 PSI. Thermal expansion or leaking pressure
reducing valves may require use of expansion tanks
or relief valves to ensure your system never exceeds
its maximum intended pressure setting.
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as items relating to
ongoing maintenance suggestions and procedures are included.
PRIÈRE DE REMETTRE cette fiche au propriétaire, préposé à l'entretien, etc., car elle contient des
articles relatifs aux suggestions et procédures d'entretien courant.
POR FAVOR deje esta hoja con el propietario, plomera de mantenimiento, etc., tiene incluída
información relativa a sugerencias y procedimientos para el mantenimiento.
062016A
3/8" Compression
x 1/2" NPSM
Compression de 3/8 po
x 1/2 po NPSM
Compresión de 3/8"
x 1/2" NPSM
www. specselect.com
061180A
HydroPower Conversion Kit
Trousse de conversion HydroPower
Juego de conversión HydroPower
PARA EL USO EN CENDIDO:
062031A
Proximity HP Adaptor
Adaptateur Proximity
(HP)
Adaptator Proximity
(HP)
HP Generator
Générateur (HP)
Generador (HP)
HP Adaptor
Adaptateur (HP)
Adaptador (HP)
Solenoid
Solénoïde
Solenoide
Control Valve
Soupape de contrôle
Válvula de control
REMARQUE : Pour une performance optimale du présent
produit, nous recommandons une pression d'alimentation de
25 à 80 psi statiques. Ce produit opère jusqu'à un maximum
de 125 psi statiques selon les exigences de ANSI et CSA.
Toutefois, nous ne recommandons pas une pression supérieure
à 80 psi. Une expansion thermale ou une fuite de pression
réduisant la force du jet peut exiger l'utilisation de vases
d'expansion ou de soupapes de décharge afin de vous assurer
que le système n'excède jamais la limite de pression maximale
suggérée.
NOTA: Para el rendimiento óptimo de este producto, recom-
endamos que la presión estática del sistema se encuentre
entre 25 y 80 PSI. Este producto funcionará con una presión
estática máxima de hasta 125 PSI de acuerdo con los
requisitos ANSI y CSA. Sin embargo, no recomendamos
061062A
presiones por encima de los 80 PSI. Las válvulas de expan-
Recharging Kit
sión térmica o reductoras de presión pueden requerir el uso
Trousse de recharge
de tanques de expansión o de válvulas de liberación para
Juego de recarga
asegurar que su sistema nunca exceda su presión máxima
especificada.
FOR USE ON:
POUR L'USAGE DESSUS :
590T1____0
591T1____0
590____HDF
591____HDF
1501T____0
3001T____0A
6__1T0__0
HydroPower (HP) Stream
Straightener Outlets
(supplied with Retrofit Kit only)
Jet HydroPower (HP) Orifices
de sorties de redressement
(fournies avec l'ensemble de
conversion seulement)
Salidas del enderezador de
flujo HydroPower (HP)
(incluídas en el juego de
readaptación únicamente)
206052 Rev. A

Publicité

loading

Sommaire des Matières pour Delta HydroPower 061180A

  • Page 1 061180A HydroPower Conversion Kit Trousse de conversion HydroPower Juego de conversión HydroPower FOR USE ON: POUR L’USAGE DESSUS : PARA EL USO EN CENDIDO: 062031A 590T1____0 Proximity HP Adaptor Adaptateur Proximity 591T1____0 (HP) 062016A Adaptator Proximity 590____HDF 3/8” Compression (HP) x 1/2”...
  • Page 2 FOR SURFACE MOUNT HOUSING: CONTROL BOX #0 ONLY POUR BOÎTIER DE MONTAGE EN SURFACE : BOÎTE DE COMMANDE N° SEULEMENT PARA CUBIERTA DE MONTAJE SUPERFICIAL: CAJA DE CONTROL #0 ÚNICAMENTE NOTE: Generator, generator adaptor, solenoid, control valve and HP electronic module supplied with this kit MUST ALL be used to properly retrofit the faucet. Components are not interchangeable.
  • Page 3 FOR SURFACE MOUNT HOUSING: CONTROL BOX #0 ONLY POUR BOÎTIER DE MONTAGE EN SURFACE : BOÎTE DE COMMANDE N° SEULEMENT PARA CUBIERTA DE MONTAJE SUPERFICIAL: CAJA DE CONTROL #0 ÚNICAMENTE STEP 3: CONNECT WATER SUPPLY HP Hose Tuyau HP Turn off water supply. If not a Proximity model, disconnect hose from outlet of solenoid Manguera HP (faucet side) and discard hose, if not already done.
  • Page 4 7 seconds and watch for a solid red light. If a solid red light is visible, begin to adjust the Control Valve by turning the light is visible, go to step 7, otherwise contact Delta Faucet handle clockwise and counter-clockwise. After each handle Technical Service.
  • Page 5 Après chaque réglage de la manette, activez le robinet pendant 7 secondes et surveillez pour voir si un témoin rouge solide paraîtra. Si un témoin rouge solide est visible, reportez-vous à l’Étape 7, autrement contactez le Service technique Delta pour robinets.
  • Page 6 7 segundos y vea si aparece la luz roja permanente. Si aparece una luz roja constante, vaya al Paso 7, de lo contrario llame al Servicio Técnico de Delta Faucet. La unidad HydroPower está lista para ser utilizada.
  • Page 7: Troubleshooting Guide

    óptimo del generador HydroPower. TROUBLESHOOTING GUIDE If you have any questions about the installation of this product or need help troubleshooting, please call Delta Commercial Technical Service at 1-800-387-8277.
  • Page 8 Delta Commercial Faucet Limited Warranty All parts of the Delta® HDF® and TECK® faucets are warranted to the original consumer purchaser to be free from defects in material, finish and workmanship for a period of five (5) years unless otherwise specifically stated in the catalogue and price book. This warranty is made to the original consumer purchaser and shall be effective from date of purchase as shown on purchaser’s receipt.