Code
Problem
Display did not
E01
receive the signal
The problem between
E02
controller and motor
The speed is
E03
abnormal
E04
over voltage
E05
over power current
E06
over voltage
safety key did not put
E07
well
Possible Reason
Cable connection
display default
controller default
motor connect wires did not
connect well
No voltage output or abnormal
voltage output of controller board
motor default
The photoelectric sensor is not
properly assembled on the motor
Poor photoelectric sensor
Failure of controller board
Input voltage too high
motor default
Failure of controller board
power current too high
Problems with the assembly
structure of the treadmill and the
motor cause motor resistance or
blockage
controller default
Input voltage too low
Failure of controller board
safety key fail off the treadmill
the safety system default
Solution
Check or replace the Cables
replace the display
replace the controller
Check that the motor wires are
connected correctly
replace the controller
replace the motor
reassemble the sensor
replace the sensor
replace the controller
adjust the voltage
replace the motor
replace the controller
adjust the power current
check the structure if it is well
replace the controller
Please check whether the power
supply line is normal
replace the controller
put the safety key well
replace the console