3.
Instructions for the qualified electrician
The differential switch must be switched off before starting.
These induction hobs are supplied with a power cable for connection of single-phase
appliances and can be modified for connection of three-phase appliances.
Connection modes for INDUCTION hobs:
THREE-PHASE CONNECTION
Warning: All supply circuits must be disconnected before accessing the terminals.
- The rated voltage of the plates is 220-240V/380-415V 3N.
- A suitably designed cable type must be selected as the mains connection cable, taking into
account the type of connection and the rated output of the cooker. The cable selected must be
of type H05RR-F 3G4 or similar and H05RR-F 4G2.5 or similar for three-phase connection. And
withstand temperatures between 60 and 90ºC depending on the type of worktop.
- The tightening torque to be applied for cable fixing shall be between 1.2 Nm and 1.5 Nm.
- Connect the earth conductor to the terminal on the block marked with the symbol
- To unlock use a screwdriver (1), moving it gently downwards (2).
- To seal it, close the cover and press lightly until the cover snaps into place.
SINGLE-PHASE CONNECTION