Télécharger Imprimer la page

IKEA NORREDSTA Mode D'emploi page 27

Publicité

ENGLISH
WARNING:
Do not ground to a gas pipe.
Our company shall not be held responsible for any damage caused by using the appliance without grounded
receptacle.
The wiring diagram covering the control circuit is located bottom of the cooktop
The main supply data must correspond to the data specified on the rating plate of the appliance.
The electrical receptacle should be placed max. 6 ft away from cooktop.
To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded
to conform with the National Electrical Code, ANSI/NFPA 70 latest edition, or Canadian Electrical Code (CSA) and all
local codes and ordinances. Refer to the illustration below.
WARNING:
Risk of electric shock, short circuit or fire by damage of the main power supply!
The main power supply lead must not be clamped, bent or trapped or come into contact with hot parts of the
appliance.
If the main power supply is damaged, it must be replaced by a qualified electrician.
A suitable wall receptacle shall be provided in the vicinity of the product.
IMPORTANT:
The gas cooker requires a 110/120VAC electrical supply to operate the ignition system. The 6' (1.8
m) power supply cord provided with the range is equipped with a 3-prong, grounded plug for protection against
shock hazard. The electric installation of the house should have its own 1 amp circuit breaker.
IMPORTANT:
You must follow all National Electrical Code and gas regulations.
In addition, be aware of local codes and ordinances when installing your services.
Grounding Plug
Grounding - Type
Electrical Outlet
CAUTION
L
N
G
GOOD
120 V AC POLARITY
Image is from blade side of plug
N
L
G
NO GOOD
SPECS
A39074
27

Publicité

loading