If the doors or windows that open directly to the outer environment do not have openings corres-ponding to the
ventilation opening specified according to the total gas power of the product, there must definitely be a fixed
ventilation open-ing in the doom. The fixed ventilation opening should also be in compliance with the values in the
gas power-ventilation opening table.
There should be a minimum clearance of 10 mm on the bottom edge of the door -that opens to the inner environ-
ment- in the room where the product is installed. You must make sure that items such as carpets, floorings, etc. do
not cover this clearance when the door is closed.
The cooker may be located in a kitchen, kitch-en/diner or a bed-sitting room, but not in a room containing a bath or
shower. The cooker must not be installed in a bed-sitting room of less than 20m3.
Do not install this appliance in a room below ground level unless it is open to ground level on at least one side.
12
Total gas
min. Ventilation
consumption (BTU/h)
opening (inch
0-6800
16
6800-10200
19
10200-13600
27
13600-20500
47
20500-27300
62
27300-34100
78
34100-39200
93
39200-44400
109
44400-52900
124
52900-58000
140
58000-64800
155
64800-81900
194