Troubleshooting
The following table will assist you in fixing faults:
Problem
Device does not start
Weak or no suction power/
throughput
Float does not close suction
opening
Dust or dirt is blown out of
the device
30
Possible cause
On/Off switch (3) turned off Check the position of the
No mains power supply
On/Off switch (3) is broken
Worn out carbon brushes
Defective motor
Suction hose (13) or nozzles
blocked
Suction pipe (12) not cor-
rectly assembled
Dirt container (6) open
Dirt container (6) full
Filter (15/16) full or clogged Empty, clean or replace the
Float in filter basket (21) in
incorrect position (e.g. due to
jerky movements)
Float in filter basket (21) de-
fective
Float in filter basket (21) not
moving
Float in filter basket (21) de-
fective
Filter (15/16) not assembled
or incorrectly assembled
Error correction
On/Off switch
Check the socket, mains con-
nection cable, plug and fuse
and have them repaired by a
qualified electrician if neces-
sary.
contact the service centre.
Removing obstructions and
blockages
Assemble the suction pipe
properly
Attaching and removing the
motor head, p. 25
Emptying the dirt container
filter
Turn off the device, the float
will sink, then switch it back
on
contact the service centre.
Release float
contact the service centre.
Attaching and removing
the filter and filter bag,