closeness might destabilize the detector. See Figure 7,
item 2.
Walk testing the detector
There are two ways for switching on the walk test mode.
SW1-6 set to LED on, SW1-5 set to Remote off
In this mode the LED indication is always enabled (constant
walk test mode).
SW1-6 set to LED on, SW1-5 set to Remote on
This setting enables the walk test input (pin 7) and the
day/night input (pin 8). This allows the user to activate LED
indication remotely by setting the detector into the day mode
and activate the walk test.
Green mode
When SW1-5 is set to Remote on, the radar is switched off
during the day mode (with no WT) to reduce current
consumption. The detector is then operating in PIR only mode.
Note:
The Day/night line must be connected to the control
panel for this mode to work.
This mode is not compliant with the EN 50131-2-4 standard.
Alarm memory
When SW1-5 is set to Remote on, alarms that occurred during
the night mode are stored in the detector memory. They are
indicated by flashing red LED when the unit switches to day
mode (walk test disabled). The memory is cleared when the
detector switches back to the night mode.
Note:
Set SW1-6 to Off to prevent showing the alarm memory
on the LEDs. See "SW1-6: LEDs" on page 5.
LEDs and outputs
To enable LEDs functionality, set SW1-6 to On, otherwise
LEDs are disabled in any condition. See "SW1-6: LEDs" on
page 5 for more details.
Table 5: LEDs and outputs
Status
Red
LED
Start up
Low voltage
PIR intruder alarm
Microwave intruder
alarm
Dual motion intruder
alarm
Dual Alarm Memory
Continuously on
Normal blinking (1 Hz)
Specifications
Detector technology:
DD1012-N
DD1012PI-N
6 / 42
Alarm
To reset
relay
Closed
Automatically after 60 s
Open
Apply correct voltage
Closed
Closed
Open
Automatically after 3 s
Closed
Switch to the night mode
Dual
Dual, pet immune
Range
Viewing angle
PIR optics
Microwave frequency
Maximum power output
Max microwave output at 1 m
Memory function
Input power
Peak-to-peak ripple immunity
Detector start-up time
Current consumption
Mounting height:
DD1012-N
DD1012PI-N
Target speed range
Alarm (NC) / Tamper relay
characteristic
Alarm time
Operating temperature
Relative humidity
Weight
Dimensions (H x W x D)
IP/IK rating
Pry-off tamper
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE
AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Carrier Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of all applicable rules
and regulations, including but not limited to the
Directive 2014/53/EU. For more information see:
www.firesecurityproducts.com
P/N 466-5632-ML • REV C • ISS 15JUL22
4, 6, 9, 12 m selectable via SW1-1
and SW1-2
78 degrees
9 high-density mirror curtains
5725 to 5875 MHz
13.46 mW
0.003 μW/cm²
Yes
9 to 15 V
(12 V nominal)
2 V (at 12 V )
60 s
5 to 17 mA (9 mA nom.)
1.8 to 2.6 m
2.3 to 2.6 m
0.2 to 3.0 m/s
80 mA 30 V , Form A
3 s
−10 to +55°C
95% max., noncondensing
120 g
126 × 63 × 50 mm
IP30 IK04
Optional (ST400)