DM50NTE
6.1
Mounting the minibar into a piece of furniture
A
NOTICE! Damage hazard
Air passing through the inlet air duct must not be heated.
Do not place the minibar near naked flames or other heat sources
(heaters, direct sunlight, gas ovens etc.).
There are four ways to mount the minibar into furniture.
1. Choose your preferred installation alternative (fig. 6, page 6).
2. Observe the required installation recess (fig. 7, page 7)
d is the thickness of the hotel's own decor
3. Observe the correct placement of the minibar and ventilation openings to
ensure a proper air flow (fig. 8, page 7).
4. Ensure the minimum clearance between the back wall of the minibar and the fur-
niture wall (fig. 0, page 8).
5. Produce the ventilation openings as shown in fig. 9, page 7.
6. Produce an additional ventilation opening in the bottom of installation recess
(fig. 0, page 8, fig. a, page 8).
Measure the distance from the door front of the minibar excluding any own
decor.
No in
fig. b, page 8
1
2
7. Fasten the minibar with the four screws(fig. b 1, page 8).
8. Insert the four plugs (fig. b 2, page 8) into the boring.
6.2
Connecting the minibar electrically
➤ Plug the AC connection cable into the AC voltage socket and connect it to the
AC mains supply.
✔ The Power Status LED lights up.
✔ The lamp lights up and the minibar starts cooling the interior.
EN
Description
Screw ø4 x 45 mm (ø0.2 x 1.8 in)
Plug
Installation
19