3) Fixed code transmitters may only be used in conjunction with Rolling code HCS transmitters, bringing the logic CVAR OFF. They are,
therefore, not usable in combination with the ARC transmitters. If the first rolling code transmitter stored is an ARC CVAR the logic is
inoperative.
4) If you want to change the type of transmitters it is necessary to proceed with a receiver reset.
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the
desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software
release.
1 – Press the button <PG>, the display goes to the first menu, Parameters "PAR".
2 – With the <+> or <-> button, select the menu you want.
3- Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
Pressing <-> with the display turned off means an impulse of P.P.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
The tables below describe the individual functions available in the control unit.
MENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Motor 1 work time. Regulates the maximum duration of the opening and closing manoeu-
TM1
vre of the motor 1.
It must be set about 4 sec. longer than the actual travel time of the automatism.
Motor 2 work time. Regulates the maximum duration of the opening and closing manoeu-
TM2
vre of the motor 2.
It must be set about 4 sec. longer than the actual travel time of the automatism.
The operating time for partial opening (pedestrian) is adjusted on motor 1.
With ENC: ON, the value is the opening percentage over the total stroke memorised dur-
TPed
ing self-setting.
With ENC: OFF, the value is the opening percentage over the time preset in TM1 param-
eter.
PMo1
The torque applied to motor 1 in the OPENING* phase is adjusted.
PMC1
The torque applie d to motor 1 in the CLOSING* phase is adjusted.
PMo2
The torque applied to motor 2 in the OPENING* phase is adjusted.
PMC2
The torque applied to motor 2 in the CLOSING* phase is adjusted.
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
TLS contact activation time.
TLS
At each manoeuvre the contact closes for the set time.
Electric lock activation time.
TLOc
If the electric lock is not used, set the parameter at 0.
16
PROGRAMMING
TO ACCESS PROGRAMMING
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
PARAMETERS (PAR)
FUNCTION
NOTES
MIN-MAX-
MEMO
(Default)
1-240-(40s)
5-180-(24s)
5-180-(24s)
1-99-(50%)
1-99-(40%)
1-99-(40%)
1-99-(40%)
1-99-(40%)
0-15-(2s)
0-60-(3s)
1-240-(60s)
0-5-(3s)