INSTALLATIONⅠ (CEILING MOUNT) / INSTALLATIONⅠ (MONTAGE AU PLAFOND)
1. Open one knock-out hole on junction
EN
box and connect wires.
(Refer to wiring diagram on page 4.)
2. Install insulated ducts to the OA and
EA adapter.
Tape
Ruban
Joist
Solive
Install outdoor hood and connect with
EN
insulated ducts.
(1) Panasonic recommends to use the accessory
Wall Cap (Model: FV-WC10VE1).
(2) If separate hoods are used, refer to local
regulations for the distance "D" between
intake and exhaust.
CAUTION
The intake air side duct must be connected
to the outside and at least 6' (2 m) away from
the exhaust of appliances such as furnace,
dryer, fuel burning appliances, etc.
Insulated duct
Conduit isolé
Adaptor insulation from
Isolation de l'adaptateur
1. Ouvrez un trou à défoncer sur la boîte de
FR
jonction et connectez les ls.
(Consultez le schéma de connexions à la page 4.)
2. Installez les conduits isolés sur les adaptateurs
AA et EA.
For 4" duct /
Conduit de 4 po
For 5" duct /
Conduit de 5 po
Installez les évents extérieurs et reliez-les aux
FR
conduits isolés.
(1) Panasonic recommande d'utiliser le capuchon
de mur accessoire (modèle : FV-WC10VE1).
(2) Si des évents séparés sont utilisés, consultez l
es réglementations locales pour la distance « D »
entre l'aspiration et l'évacuation.
ATTENTION
Le conduit d'air côté alimentation doit provenir de
l'extérieur et à une distance d'au moins 2 m (6 pi)
de l'échappement des appareils tels qu'une fournaise,
une sécheuse, des appareils à combustibles, etc.
Exhaust hood with backdraft ap (s)
Évent de sortie avec clapet
antirefoulement
Intake hood with bird screen
(No backdraft ap (s))
Évent d'entrée avec grille à oiseaux
(pas de clapet antirefoulement)
Insulated duct
Conduit isolé
Tape
Ruban
Adaptor
Adaptateur
Insulated duct
Conduit isolé
Tape
Ruban
Adaptor
Adaptateur
7