BTL KKJJ00- _ _ _ _ -C05A _ _ _ 0-000S32
Magnetostrictive Linear Position Sensor – Rod Style
9
Technical data
The specifications are typical values for and at 24 V DC,
room temperature and a measuring length of 500 mm in
conjunction with the BTL-P-1013-4R, BTL-P-1013-4S,
BTL-P-1012-4R or BTL-P-1014-2R position magnet.
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at www.balluff.com
on the product page.
9.1
Ambient conditions
Ambient temperature
Storage temperature
Relative humidity
Operating pressure
Short-term pressure load
Typ. temperature coefficient
1)
Shock rating as per
EN 60068-2-27
2), 3)
Continuous shock as per
EN 60068-2-27
2), 3)
Vibration as per EN 60068-2-6
Protection as per IEC 60529 (when
threaded together)
9.2
Detection range/measuring range
Measuring length
Analog resolution position
...-C05AA/-C05A1...
...-C05AE/-C05A5...
Repeat accuracy
with measuring length
≤ 500 mm
with measuring length
> 500 mm
Length-dependent measuring
frequency
Measuring length ≤ 1270 mm
Measuring length > 1270 to
≤ 2650 mm
Measuring length > 2650 mm
Linearity deviation
4)
with measuring length
≤ 500 mm
with measuring length
> 500 mm
Detectable velocity
Analog resolution speed
...-C05AA/-C05A1...
...-C05AE/-C05A5...
www.balluff.com
−40...+85 °C
−40...+100 °C
≤ 90%, non-
condensing
≤ 600 bar
750 bar (10 × 1 min)
≤ 30 ppm/K
100 g/6 ms
50 g/2 ms
12 g, 10 ...2000 Hz
2), 3)
IP67, IP69K
25...4000 mm
183 μV / ≥ 4 μm
351 nA / ≥ 4 μm
≤ ±10 µm
≤ ±0.002% FS
1000 Hz
500 Hz
250 Hz
±60 μm
±0.012% FS
≤ 10 m/s
183 μV / ≥ 0.1 mm/s
351 nA / ≥ 0.1 mm/s
9.3
Electrical data
Operating voltage U
b
Current draw (at 24 V DC)
...-C05AA_C0-.../...-C05A1_C0-...
...-C05AE_C0-.../...-C05A5_C0-...
Power consumption
...-C05AA_C0-.../...-C05A1_C0-...
...-C05AE_C0-.../...-C05A5_C0-...
Overvoltage protection
Voltage-proof up to (GND – Housing)
...-C05AA/-C05A1...
Output current
...-C05AE/-C05A5...
Load resistance R
Lc
9.4
Electrical Connection
Short-circuit protection
Protected against polarity reversal
1)
Measuring length 500 mm, position magnet in the middle of the
measuring range
2)
Individual specifications as per Balluff standard
Resonant frequencies excluded
3)
Configuration for one position magnet
4)
A prerequisite is that no current can flow between GND and 0 V in the
5)
event of polarity reversal.
10...30 V DC
≤ 65 mA
≤ 85 mA
≤ 1.6 W
≤ 2.1 W
U
up to 36 V DC
b
500 V DC
≤ 5 mA
≤ 500 ohm
Signal output to
GND and to
30 V DC
U
up to 30 V DC
5)
b
english