BTL KKJJ00- _ _ _ _ -C05A _ _ _ 0-000S32
Magnetostrictive Linear Position Sensor – Rod Style
6
Commissioning and operation (continued)
6.2
Operation
Characteristic
BTL
curve
Rising
...-C05AA...
...-C05AE...
Falling
...-C05A1...
...-C05A5...
Tab. 6-1:
Table of values
6.3
Operating notes
–
Some settings can be modified (see Configuration with
the Balluff Engineering Tool (BET) on page 16).
–
Regularly check function of the BTL and all associated
components.
–
Take the BTL out of operation whenever there is a
malfunction.
–
Secure the system against unauthorized use.
–
Check fasteners and retighten if needed.
6.4
Maintenance
The product is maintenance-free.
www.balluff.com
Null point
Unit
Minimum
value
V
−0.4
mA
3.6
V
10.4
mA
20.4
Null value
End value
0
10.0
4.0
20.0
10.0
0
20.0
4.0
End point
Maximum
Error value
value
10.4
10.5
20.4
1.8
−0.4
10.5
3.6
1.8
english
15