BTL KKJJ00- _ _ _ _ -C05A _ _ _ 0-000S32
Magnetostrictive Linear Position Sensor – Rod Style
7
Configuration with the Balluff Engineering Tool (BET) (continued)
7.3
Configuration options
DANGER
Uncontrolled system movement
When starting up and if the magnetic encoder system is
part of a closed loop system whose parameters have
not yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► The system must be taken out of operation before
configuration.
► The BTL may only be connected to the master box
for configuration.
► The master box must be removed after
configuration.
Prerequisites
BTL connected to IO-Link master and PC.
Software correctly installed.
BTL connected to the power supply.
Position magnet on BTL.
Further information can be found in the
configuration guide online at www.balluff.com
on the product page.
Position magnet and outputs
Possible factory default of number of magnets:
One position magnet
Flexible Magnet Mode (FMM)
Two outputs can be assigned independent of each other.
The number of magnets set can be fixed or flexible.
Fixed setting, one position magnet: With the setting
of one position magnet, a second position magnet is
ignored.
Flexible Magnet Mode (FMM): With Flexible Magnet
Mode the number of magnets is flexible so that it can
also be changed during operation. If there are two
magnets on the BTL, the respective output function is
output via the outputs. If there is only one position
magnet on the BTL, its output function is always output
via output 1. As there is no second position magnet,
output 2 always issues the error value.
www.balluff.com
Functions of the outputs
Position: in measuring range.
Position difference: Distance between two magnets.
The selection is only possible if Flexible Magnet Mode
(FMM) is selected for the number of magnets.
Speed: Speed of the position magnet. The sign
displays the movement direction. Movement from zero
point to end point is displayed with a positive sign.
Movement from end point to zero point is displayed
with a negative sign. The maximum measurable speed
range is −10...+10 m/s.
Status of the outputs
Status of the analog outputs is readable.
Freely configurable curve
Zero and end points can be taught-in (Teach-In).
The distance between zero point and end point must
be at least 10 mm.
The characteristic curve can be inverted.
The limits can be adjusted to the measuring range.
The error value can be set according to the limits.
Condition with two magnets
The distance between two magnets must be at least
≥ 65 mm.