GARANT Grid vacuum plate Venturi system VRV0
de
Fault
Vacuum plate changed over
to vacuum connection: Oper-
en
ating vacuum not achieved or
is too low, and the vacuum
pump is running
cs
The clamping face of the va-
cuum plate is damaged
da
The restraining force is insuf-
ficient to machine the work-
piece
es
fi
10. Cleaning
fr
Clean with a cloth or compressed air.
Do not use any corrosive cleaning agent.
hr
11. Storage
Store in an enclosed dry room.
Do not store in the vicinity of acidic, aggressive, chemical substances, solvents, humidity and dirt.
hu
Protect against direct sunlight.
Store at temperatures between +15° C and +35 °C.
Relative atmospheric humidity max. 60%
it
12. Spare parts
Use only original replacement parts and wearing parts.
lt
Use only a Ø 4 mm sealing cord.
13. Disposal
Comply with the national and regional environmental protection and disposal regulations for correct disposal or recycling.
nl
Segregate items into metals, non-metals, composite materials and consumables and dispose of them responsibly.
14. Technical data
pl
Article no. / type
Length
Width
pt
Height
Grid
ro
Operating medium
Permissible operating pressure
ru
Operating pressure for maximum vacuum
Maximum vacuum
sl
Ambient temperature
Operating medium temperature
Compressed air hose
sv
or hose coupling adaptor
14
Possible cause
Leaky vacuum hoses
Dirt between the workpiece
and vacuum plate
Seal defective or not fitted
Kink in the vacuum hoses
Defective machining of the
workpiece
Clamping area is too small
Diameter of the vacuum
hoses too small, or vacuum
hoses too long
Power of the vacuum pump
insufficient
Action
Change the vacuum hoses
Clean the faces of the work-
piece and vacuum plate
Change the seal
Align the vacuum hoses cor-
rectly
Check the machining pro-
gram
Increase the clamping area
Use additional restraints for
workpiece
Increase the diameter of the
vacuum hoses, or reduce the
length of the vacuum hoses
Increase the power of the va-
cuum pump
384900 / VRV0
200 mm
125 mm
21 mm
12.5 mm
Compressed air to ISO 8573-1:2010 [7:4:4]
not oiled
max. 7.0 bar
4.0 bar
91% (approx. 93 mbar at standard pressure)
0 °C - 60 °C
0 °C - 60 °C
Ø 10 mm
7.2 mm
Performed by
Trained specialist for mechan-
ical work
Trained person
Trained specialist for mechan-
ical work
Trained specialist for mechan-
ical work

Publicité