Make sure that parts of the body never come between moving parts. There is a risk that parts of the
body may be crushed or cut.
•
Make sure that the deadman's handle does not become jammed.
•
Stop immediately if the system makes strange noises or displays aberrant behaviour.
•
Stop immediately if the equipment leaks oil. Oil escaping under pressure can penetrate the skin and
cause serious injury. Go immediately to a hospital with a person who is injected with oil for medical
help. Give a specification of the oil to the medical staff.
•
Return inactive equipment immediately to the tool station.
•
Always adhere to the safety regulations that apply to other equipment that is used in the operation.
2.11
Safety regulations with respect to maintenance
•
Wear personal means of protection when performing maintenance tasks.
•
Never work in a way that could jeopardize safety.
•
Make sure that the equipment cannot roll away or tip over. The control and drive must be switched
off and safeguarded against unexpected activation.
•
Make sure that moving parts do not move unexpectedly.
•
Used or leaked fluids, and any other products consumed during the activities, must be collected and
disposed of in an environmentally responsible way.
3
Description
3.1
Equipment
The combi tool can be used independently because of the battery-driven hydraulic system.
The tool is produced as a hand tool that can be operated by one person.
The tools are suitable for cutting, spreading and squeezing constructional elements of vehicles during
rescue operations. They can squeeze material tightly or squash it and thus create weak pivots or places
that are easier to cut. They can also push parts apart. By placing accessories on the points, materials
can be pulled together.
The battery energizes the electric motor. The electric motor operates a multi-stage piston pump that can
build up a maximum system pressure of 720 bar. Stage switching is electronically controlled for
maximum speed at the required pressure.
NOTE
The tool and battery pack can be put fully into fresh water at a maximum depth of 1 meter for
30 minutes.
3.2
Type designation
Example: PCT50
/i
Digit
Example
1-3
PCT
4-5
50
3.3
Product identification
Refer to Fig. 2.
PCT50
Description
P = Pentheon
CT = Combi Tool
Type indication
916.400.139_002
EN
39