Télécharger Imprimer la page

LG LMU186HV Manuel D'instructions page 13

Masquer les pouces Voir aussi pour LMU186HV:

Publicité

Installation
Installation
[Standard /Artcool Mirror Type]
Connecting the piping
1. Prepare the indoor unit's piping and drain
hose for installation through the wall.
2. Remove the plastic tubing retainer(see the
illustration on the right) and pull the tubing
and drain hose away from chassis.
3. Route the indoor tubing and the drain hose to
the required piping hole position.
4. Insert the piping, drain hose, and the
connecting cable into the piping hole.
5. Insert the connecting cable into the indoor unit.
• Don't connect the cable to the indoor unit.
• Make a small loop with the cable for easy
connection later.
6. Tape the drain hose and the connecting
cables.
Connecting
pipe
Drain hose
For right rear piping
7. Indoor unit installation
• Hang the indoor unit from the hooks at the
top of the installation plate.
• Insert the spacer etc. between the indoor
unit and the installation plate and separate
the bottom of the indoor unit from the wall.
12 Multi Air Conditioner
Tape
Connecting cable
For left rear piping
Indoor unit
Spacer
Installation plate
80(33/16)
Connecting
cable
Drain pipe

Publicité

loading