Télécharger Imprimer la page

SFA SANICOMPACT Silence ECO+ Notice D'installation page 13

Masquer les pouces Voir aussi pour SANICOMPACT Silence ECO+:

Publicité

UK
1
DESCRIPTION
This device is not designed for
persons (including children) with
limited physical, sensory or mental abilities,
or those with minimal experience and know-
ledge, unless they are monitored and are gi-
ven the necessary instructions for using the
device, with the help of a person responsible
for their safety. Monitor children and make
sure they do not play with the device.
2
APPLICATIONS
Sanicompact ® is a specially designed WC with
an integral pump / macerator to discharge WC and
washbasin waste*. (*: depending on the model).
3
INSTALLATION
The fitting and working of your appliance must meet
local regulations and the EN 12056-4 standard.
To optimise the latest technical developments
concerning soundproofing incorporated into this
unit, it is important to:
• position the WC pan so that it is not in contact
with a partition or wall of the room
• place the WC pan on a perfectly level surface
• fix the discharge pipe correctly, with distances of
not more than one metre between the fastenings.
CONNECTION TO THE WATER SUPPLY
Connect the water supply hose to a shut off valve.
Caution: The quality of the rinsing of the bowl
depends on the water pressure.
WARNING: for a correct rinsing, the water pres-
sure should be at least 25 PSI (1,7 bars).
Note: In an area where water is not pure (dirty,
sandy), we advise you to add a filter between the
shut off valve and the toilet to prevent clogging
of the solenoid valve.
CONNECTION TO THE ELECTRICAL SUPPLY
The electrical installation should
be carried out by a qualified person.
The unit requires a 220/240V single phase AC
50 Hz supply (UK specification).
The power supply circuit of the appliance must
be earthed (Class I) and protected by a GFCI
high sensitivity (30mA). Warning: Ensure the
electricity is turned OFF at the main switch
board before wiring to connector.
All wiring must conform to BS7671, 1992 require-
ments for electrical installations. Do not connect the
unit to a conventional plug and socket. It must be
wired into a fused, unswitched, fixed wiring
connector fitted with a 5 amp fuse. The wires
in the mains lead are coloured in accordance with
the following code:
Brown - Live
Blue - Neutral
Green/Yellow - Earth
The connection must be used exclusively to
power the device. All work on cable, pressure
chamber and motor should only be carried out
by a qualified Saniflo servicing agent, as special
tools are required. Please do not cut/shorten
the electrical supply cable which can make it
very difficult to remove in the event of a service
requirement.
4
COMMISSIONING THE UNIT
Connect to the power supply. Wait 20 seconds:
appliance initializing.
Open the water tap to rinse well. Start the nor-
mal flush by pressing the dark grey button. Put
a few sheets of toilet paper down in the bowl
and flush again.
PROGRAMMING
SANICOMPACT® Eco is controlled by an elec-
tronic programmer. Duration of operation varies
according to the cycle chosen.
- Eco flush (light grey button)
- Normal flush (dark grey button)
You can lengthen the rinse if the default flush is
not enough.(Low supply pressure)
To re-programme:
• Press the two grey buttons at the same time
for 5 seconds. (model without wash basin option)
• Press the dark grey button for 5 seconds
(model with wash basin option)
• The motor runs for 2 seconds, this means you
have entered programming mode.
• Each time you press the dark grey button you
increase the length of the flush by 1 second: each
time you press it will be validated by the motor
running for a short period.
• Each time you press the light grey button you
decrease the length of the flush by 1 second:
each time you press it will be validated by the
6
FAULT FINDING / REMEDIES
IN ALL CASES, YOU MUST DISCONNECT
THE MACERATOR FROM THE POWER SUPPLY
SYMPTOMS
• After pressing the flush button
(24), the flush does not start
• The cycle is triggered but not
much water flows into the
toilet bowl
• The cycle is triggered but no
water flows into the toilet bowl
• The cycle is carried out correctly
and the motor runs, but the
water in the toilet bowl is only
removed gradually or is not
removed at all
•The cycle is carried out correctly
but a lot of water stays in the
toilet bowl
• The motor emits a rattling or
crunching sound, hums, but
does not run
•The motor intermittently
activates
• Smells emanate from the
washbasin trap
• The water from the washbasin
does not run out automatically
7
GUARANTEE
2 year guarantee as from its date of purchase subject to correct installation and correct use.
Only the disposal of toilet paper, faecal matter, and waste water will be under
guarantee. Any damage due to foreign bodies such as cotton, condoms, sanitary towels,
wet wipes, food, hair, metal, wood or plastic objects, will not be under guarantee. Solvents, acids
and other chemicals can also cause damage to the unit, and will invalidate the guarantee.
5
motor running for a short period.
To exit programming mode:
• Do nothing for several seconds
Note : Duration of operation varies according to
the cycle chosen.
Operating wash basin: Please make sure that the
wash basin tap draining into the sanicompact is
properly shut off after usage and not dripping.
5
MAINTENANCE
WARNING !!! In the event of prolonged absence
it is essential to turn off the water supply to protect
the installation against sub zero temperatures.
CARE OF YOUR UNIT
In order to remove scale and clean the mace-
rator and the bowl, use the SANIFLO Cleanser/
Descalent.
.Disconnect the macerator power supply,
.Pour an amount of cleanser into the pan
.Leave it to stand for 1 or 2 hours,
.Re-connect the macerator power supply,
.Rinse by operating the flushing system twice.
Carry out the operation once every 3 months on
average, but the frequency may need to be changed
depending on the hardness of the water.
PROBABLE CAUSES
• The electrical power supply
• Restore the electrical supply and
is not active or the electrical power
• Otherwise, ask an approved
supply is defective
• The inlet filter on the solenoid
• Clean the solenoid valve filter
valve (28) is clogged.
• Insufficient water supply flow
• Modify the installation
• The stopcock is closed
• Open the stopcock
• The solenoid valve (28) is faulty
• Consult the SFA customer
service
• Insufficient water supply flow
• Increase the rinsing time
• The valve flap on the siphon (23)
(programming)
• Clean or replace the valve flap
is leaking
on the siphon (23)
• The drain height is too great.
• Modify the installation
• The non-return valve is faulty
• Clean or replace the non-return
valve
• Foreign object into the box
• Remove the foreign body
• Problem with the motor or the
• Otherwise, ask an approved
control system
repair agent to intervene
• The connected sanitary devices
• Check the installation upstream
• Clean or replace the non-return
are dripping water
• The non-return valve is faulty
valve
• The washbasin trap is dry
• Install a vacuum breaker
• Washbasin trap blocked
• Remove the foreign body
• Problem with the automatic
• Otherwise, ask an approved
repair agent to intervene
control
REMEDIES
check the electrical power supply
repair agent to intervene

Publicité

loading