Read this installation manual completely to ensure proper installation, then file it with the
Installation
owner or maintenance department. Compliance and conformity to drain requirements and
other local codes and ordinances is the responsibility of the installer.
Separate parts from packaging and make sure all parts are accounted for before discarding
Packing List
any packaging material. If any parts are missing, do not begin installation until you obtain the
IS
T H
E
missing parts.
S ID
U P
Flush the water supply lines before beginning installation and after installation is complete.
Test the unit for leaks and adequate water flow. Main water supply to the eyewash should be
"ON" at all times. Provisions shall be made to prevent unauthorized shutoff.
The ANSI Z358.1 standard requires an uninterrupted supply of flushing fluid. Bradley plumbed
emergency fixtures require a minimum of 30 PSI (0.21 MPa) flowing pressure. Flushing fluid
should be tepid per ANSI Z358.1.
The inspection and testing results of this equipment should be recorded weekly to verify
proper operation. This equipment should be inspected annually to ensure compliance with
ANSI Z358.1.
Workers who may come in contact with potentially hazardous materials should be trained
regarding the placement and proper operation of emergency equipment per ANSI Z358.1.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY
FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
For questions regarding the operation or installation of this product, visit www.bradleycorp.
com or call 800.BRADLEY (800.272.3539).
Product warranties and service parts information may also be found under "Products" on our
web site at bradleycorp.com.
Installation
NOTICE! Avoid cleaners containing organic solvents, alcohols, and hydrocarbons.
Rinse with water after cleaning.
Supplies Required:
• Teflon tape and/or pipe sealant
• ½" NPT water supply inlet (30–90 psi)
• #10 screw to mount hose holder (anchor optional)
• Backflow prevention device as required by UPC, IPC and/or local plumbing codes
Step 1: Mount the Hose
1 . Rough in ½" NPT supply piping (by installer) from the wall where the hose holder will be mounted .
2 . Mount the hose holder to the wall with a #10 screw (supplied by installer) . Install wall anchor if desired .
Step 2: Connect water supply
Apply pipe sealant (supplied by installer) to all male threaded pipe joints.
1 . Connect one end of the drench hose to the ½" NPT water supply .
2 . Slide the handle over the hose .
3 . Install the valve body onto the other end of the hose . Thread the handle onto the valve body .
4 . Open the water supply line . Test for leaks and adequate water flow .