Parameter
Parameter Name Parameter Range Default
Code
N04
Infrared receiver of
IDU display box
N05
Whether buzzer of
the IDU rings
N06
Light (display box)
setting
N07
Temperature unit
N08
Mode switch interval
in auto mode (min)
N09
Heating and cooling
temperature
difference setting in
auto mode
N11
Set outdoor temperature
for auxiliary heat
source/alternative heat
source to turn on
N12
Indoor temperature
for auxiliary heat
source/alternative
heat source to turn on
N13
T1 temperature
difference for auxiliary
heat source/alternative
heat source to turn on
N14
T1 temperature
difference when
auxiliary heat
source/alternative
heat source is off
N15
Auxiliary heat source
used alone
Value
00/01
00
00/01/02
02
00/01
01
00/01
00
00/01/02/03
00
00/01/02/03/04/05/06
00
/07/08
Celsius: -25°C to 20°C
0°C
Fahrenheit:
-13°F to 68°F
10°C to 30°C
24°C
0-7
3
0-10
5
00/01
00
46
Remarks
00: Yes; 01: No
00: No; 01: Yes
02: Only the display box rings.
00: Off; 01: On
00: Celsius; 01: Fahrenheit
00: 15 minutes; 01: 30 minutes;
02: 60 minutes; 03: 90 minutes
00: 0°C; 01: 1°C; 02: 2°C;
03: 3°C; 04: 4°C; 05: 5°C;
06: 6°C; 07: 7°C; 08: 8°C
Note: Accuracy is 1°C or 1°F
Accurate to 1°C
0 to 7 indicate 0 to 7°C/°F
(The value is accurate to 1°C or 1°F.)
0 to 10 indicate -4 to 6°C/°F.
(The value is accurate to 1°C or 1°F.)
00: Disable; 01: Enable
V.1