EN
Failure
code
96
BAT1 other failure.
BAT 2 over-heated error.
97
BAT2 low temperature.
98
99
BAT2 under voltage.
100
BAT2 communication error.
101
BAT2 unbalanced discharge.
102
BAT2 NTC failure.
103
BAT2 communication interruption.
104
BAT2 other failure.
BAT 3 over-heated error.
105
BAT3 low temperature.
106
107
BAT3 under voltage.
108
BAT3 communication error.
109
BAT3 unbalanced discharge.
110
BAT3 NTC failure.
111
BAT3 communication interruption.
112
BAT3 other failure.
113
PMU has no available battery pack.
PMU other failure.
114
LCD screen hall sensor.
120
* If you cannot find the solution to these problems, go to the service center.
12
TECHNICAL DATA
Voltage
Problem
82 V
English
Replace new battery
Shut down and restart after the battery pack cools
down. If the problem cannot be solved, consider
replacing the battery pack.
If the working environment temperature of the
equipment meets the low temperature working en-
vironment of the battery pack, it is necessary to
consider replacing the battery pack.
Recharge the battery.
Replace new battery.
Replace new battery.
Replace new battery.
Replace new battery.
Replace new battery.
Shut down and restart after the battery pack cools
down. If the problem cannot be solved, consider
replacing the battery pack
If the working environment temperature of the
equipment meets the low temperature working en-
vironment of the battery pack, it is necessary to
consider replacing the battery pack.
Recharge the battery.
Replace new battery.
Replace new battery.
Replace new battery.
Replace new battery.
Replace new battery.
Restart the mower and replace new battery.
Release the bail and restart the mower. If the fail-
ure is still occurred, replace the PMU controller.
Pull the self-propelled lever to the lowest position.
If the failure is still occurred, replace the hall com-
ponents.
Battery model
22
Solution
82BD250/82BD400/82BD500/82B
D800 and other Greenworks Com-
mercial 82V series