sigfox RC1 ANALOG PWR - Guide utilisateur / User guide version V2.0.2
4.1.7
Summary of the conditions of the transmission of the uplink frames
The table below summarizes the conditions of the transmission of the different uplink frames:
Code
0x10
Product configuration data frames
0x11
0x12
FR
0x13
0x14
0x20
Frames of information on the network
configuration
0x30
Keep Alive frame
EN
0x31
Reply frame to a register value request in
a downlink frame
0x42
Data Frame
Description
• Start-up of the product
• Exit from the configuration mode (AT Command)
• Reception of a downlink frame 0x01
• Periodically if the inputs are disabled (period defined by the register 300)
• Start-up of the product
• Exit from the configuration mode (AT Command)
• Reception of a downlink frame 0x02
• Periodically in «event» mode
• Reception of a downlink frame 0x40
• Start-up of the product
• Event on an digital input configured in event mode
• Passing a threshold (event mode)
• The end of the period on input configured in periodic mode
www.ime.de
Sending conditions
Page
72