Pulse Transceiver pulse interfaces Guide utilisateur / User Guide Version 2.0.0 adeunis ® 283 rue Louis Néel - Parc Technologique Pré Roux 38920 CROLLES - France www.adeunis.com...
Page 2
Ninguna parte de este documento puede ser reproducida o transmitida (en fotocopias electrónico o en papel, o) sin el acuerdo adeunis®. Este documento puede ser modifi cada sin previo aviso. Todas las marcas comer- ciales mencionadas en esta guía son el tema de los derechos de propiedad intelectual.
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 TABLE DES MATIÈRES FRANCAIS INFORMATIONS sigfox Pulse 1.1. Description générale 1.2. Encombrement 1.3. Carte électronique 1.4. Spécifications Techniques 1.4.1 Caractéristiques générales 1.4.2 Autonomie 1.4.3 Compatibilité capteurs 1.4.4 Caractéristiques des interfaces physiques 1.4.4.01 Interface d’entrée signal pulse 1.4.4.02 Interface d’entrée signal fraude FONCTIONNEMENT DU PRODUIT...
Page 4
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 5.2. Installation du joint presse étoupe 5.3. Montage des compteurs sur les borniers à vis 5.4. Fermeture du boîtier 5.5. Démarrage du produit via aimant INSTALLATION ET UTILISATION 6.1. Positionnement correct des émetteurs 6.2.
Page 5
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 4.1.10 Summary of the conditions of the transmission of the uplink frames 4.2. Downlink frames 4.2.1 Product configuration request frame 4.2.2 Network configuration request frame 4.2.3 Frame for adding an offset to pulse counters 4.2.4 Specific register value request frame 4.2.5...
Ce document et l’utilisation de toute information qu’il contient, est soumis à l’acceptation des termes et conditions adeunis®. adeunis® ne donne aucune garantie sur l’exactitude ou l’exhaustivité du contenu de ce document et se réserve le droit d’apporter des modifi cations aux spécifi cations et descriptions de produit à tout moment sans préavis.
Page 8
Pulse - Guide utilisateur / User guide version V2.0.0 Déclaration UE de Conformité Nous adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Déclarons que la DoC est délivrée sous notre seule responsabilité et fait partie du produit suivant : Modèle produit :...
Page 10
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS ENVIRONNEMENTALES Tous les matériaux d’emballage superfl us ont été supprimés. Nous avons fait notre possible afi n que l’emballage soit facilement séparable en trois types de matériaux : carton (boîte), polystyrène expansible (matériel tampon) et poly- éthylène (sachets, feuille de protection en mousse).
Page 11
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS D’USAGE • Avant d’utiliser le système, vérifi ez si la tension d’alimentation fi gurant dans son manuel d’utilisation corres- pond à votre source. Dans la négative, consultez votre fournisseur. •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 1. sigfox Pulse NOTE IMPORTANTE : le démarrage du sigfox Pulse ne peut se faire que grâce à un aimant. Description • Le sigfox Pulse est un émetteur radio prêt à l’emploi permettant de transformer tout type de compteur en un compteur sans-fil (smart meter).
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 1.2. Encombrement Valeurs en millimètres 49,50 1.3. Carte électronique 49,50 Antenne interne Module RF Batterie interne Protocole sigfox 49,50 Ports pour configuration produit Borniers à vis pour connexion capteurs Page of 100...
Les valeurs ci-dessous sont des estimations faites dans certaines conditions d’utilisation et d’environnement. Elles ne représentent en aucun cas un engagement de la part d’adeunis®. 1.4.3 Compatibilité capteurs Exemple de compteurs testés par adeunis® (liste non exhaustive) : Type Type capteur...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 1.4.4 Caractéristiques des interfaces physiques 1.4.4.01 Interface d’entrée signal pulse Le schéma de principe est le suivant : Valeurs absolues maximum Unité Tension minimale d’entrée - 0.7 Tension maximale d’entrée Caractéristiques électriques Unité...
Pulse - Guide utilisateur / User guide version V2.0.0 2. FONCTIONNEMENT DU PRODUIT 2.1. Modes de fonctionnement NOTE IMPORTANTE : adeunis® utilise le format de données Big-Endian Le produit dispose de plusieurs modes de fonctionnement : MODE PARC Présence d’un aimant sur le produit >6s...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 2.1.4 Mode REPLI Le produit entre dans ce mode très basse consommation suite à la détection d’un niveau de batterie trop faible. Dans ce mode le produit se réveille toutes les 5 secondes pour faire clignoter 2 fois la LED rouge. Le remplacement de la pile (si le produit est en version pile changeable) suivi de l’application de l’aimant permet de sortir de ce mode pour retourner en mode d’EXPLOITATION.
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 2.2.2 Transmission périodique avec historique Le produit permet l’accumulation de plusieurs valeurs de compteurs successives avant la transmission périodique de l’ensemble des valeurs selon le schéma suivant : Produit en veille Période Impulsion historisation...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 2.2.3 Transmission sur dépassement de seuil de débit Le produit permet la détection de dépassement d’un seuil de débit pour chaque entrée de comptage selon le schéma suivant : Produit en veille Impulsion Période détéctée et...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Les paramètres associés à ce mode de fonctionnement sont : • Activation et configuration des entrées (registre S320) • Type d’historique (période d’historisation et nombre de valeurs à accumuler) (registre S321) •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Exemple : Registre Codage de la valeur Valeur Résultat S320 Hexadécimal 0x39 Voie A : • Activée • Compteur autre que gaz • Entrée fraude activée Voie B : • Activée •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 2.2.6 Détection de fuite Le produit permet la détection de fuite sur chaque entrée de comptage selon le schéma suivant : Produit en veille Période Impulsion Période de calcul débit détectée et 24h atteinte atteinte...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Exemple : Registre Codage de la valeur Valeur Résultat S320 Hexadécimal 0x39 Voie A : • Activée • Compteur autre que gaz • Entrée fraude activée Voie B : • Activée •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 2.3. Fonctionnement des LEDs Mode Etat Led Rouge Etat Led Verte Emission de trame (mode TEST seulement) Allumé pendant l’émission Réception de trame (mode TEST seulement) Allumé pendant la réception d’une trame de downlink Produit en mode Park Eteinte...
Vous devez voir apparaitre lors de la connexion un périphérique série USB avec un numéro de port COM associé. Si vous ne voyez aucun périphérique de ce type, vous devez installer le driver USB pour ce périphérique, disponible sur notre site internet : https://www.adeunis.com/produit/pulse/ Sélectionnez : •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 3.2. Mode commande Utiliser un terminal port COM pour communiquer avec le produit. Nous utilisons le soft terminal port COM HERCULES disponible en télécharge- ment gratuit à l’adresse suivante : https://www.hw-group.com/products/hercules/index_en.html •...
ATTENTION : par défaut le code PIN est désactivé. A mani- puler avec précaution car si l’utilisateur met en place un code PIN et qu’il oublie celui-ci le produit sera bloqué et devra être retourné à adeunis® pour déblocage. AT/V Affiche les versions logicielles Applicatif et RTU APP_8230EAA_PRG1706_V01.02.02:RTU_RTU_WM-...
ATTENTION : par défaut le code PIN est désactivé. A manipuler avec précaution car si l’utilisateur met en place un code PIN et qu’il oublie celui-ci le produit sera bloqué et devra être retourné à adeunis® pour déblo- cage. Défaut : 0 Permet de passer le produit dans l’un des modes suivants :...
Page 29
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Configuration des entrées Hexadéci- Défaut : 0x11 (voies A et B) Pour la voie A : • Bit 0 : Activation voie A • Valeur 0 : voie désactivée • Valeur 1 : voie activée •...
Page 30
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Valeur courante du compteur Décimal Défaut : 0 voie A Min/max : 0 à (232-1) Unité : nombre d’impulsions En mode commande, il est possible de venir écrire une nouvelle valeur dans ce registre (par exemple une valeur d’initialisation, une valeur d’ajustement…).
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 3.4.2 Registres réseau La liste des registres ci-dessous permet de modifier les paramètres réseau du produit. Cette liste est accessible en mode PROVIDER suite à l’exécution de la commande ATT63 PROVIDER. Ces registres doivent être manipulés avec précaution car susceptibles d’engendrer des problèmes de communication ou de non-respect de la législation en vigueur.
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 4. DESCRIPTION DES TRAMES 4.1. Trames montantes (uplink) Les trames montantes du produit vers le réseau (uplink) ont une taille variable selon les informations transmises. 4.1.1 Octets fixes Les deux premiers octets de la trame sont systématiquement dédiés pour indiquer le code de la trame et le statut comme présenté ci-dessous : Code Status PAYLOAD...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 4.1.2 Trames d’information sur la configuration du produit Suite à la réception d’une trame descendante (downlink) avec le code 0x01 ou lors du passage en mode exploitation (sortie du mode PARC ou COMMANDE), les trois trames suivantes (0x10, 0x11 et 0x12) représentant la configuration applicative du produit sont transmises : 3 et 4 8 et 9...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 2 à 3 4 à 5 Code Status PAYLOAD 0x12 Cf Status S330 S331 0x12 0xA3 0x0003 0x0005 Description de la trame : • Octets 2 à 3 : registre 330, nombre de périodes quotidiennes en dessous du seuil de fuite (voie A) •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Dans l’exemple en gris cela donne : • Octet 2 : Alarmes = 0x19 soit (00011001) en binaire ce qu’y donne : • Bit 0 = 1 – Sur-débit sur la voie A •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Dans l’exemple en gris cela donne : • Octets 2 à 5 : compteur voie A = 0x00015C4F soit 89 167 impulsions • Octets 6 à 9 : compteur voie B = 0x0000F74A soit 63 306 impulsions 4.1.7 Trame d’alarme Cette trame (0x47) est émise si le débit mesuré...
Page 37
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 • Octets 9 à 10 : Delta B1 : Variation de l’index de la voie B pendant l’intervalle s’étendant de 20 à 30 minutes après l’envoi de la trame précédente. Dans l’exemple en gris cela donne : •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 4.1.9 Trame de données périodique avec historique sur 24 heures Treize trames (0x48) sont émises toutes les 24 heures si la fonctionnalité est activée via le registre S321. Trame 1/13 : 3 à...
Page 39
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Dans l’exemple en gris cela donne : • Octet 2 Index trame : Index de cette trame dans une séquence multi-message = 2 (3ième trame) • Octets 3 à 4 : Delta A2 : Variation de l’index de la voie A = 0x0100 soit 256 impulsions de plus dans les 3 heures qui ont suivi •...
(RX window) pendant maximum 30 secondes, conformément au schéma ci-dessous : La configuration de la politique d’envoi de demande d’acquittement dans le produit adeunis® diffère selon que le produit est en mode pério- dique ou évènementiel : •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 4.2.2 Trame de demande de la configuration du réseau Cette trame permet de faire savoir au produit via le réseau qu’il doit réémettre la trame montante de configuration du réseau (0x20). Code PAYLOAD 0x02...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Description de la trame : • Octets 1 à N : CONFIDX (8bits): indice du registre à envoyer. Le registre correspondant est 300 + valeur de CONFIDX. Par exemple, si CONFID1 = 20, le transmetteur enverra en retour la valeur du registre 320. La trame descendante associée porte le code 0x31 (voir paragraphe 4.1.5).
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 5. PRÉPARATION 5.1. Démontage du boîtier Le produit est livré démonté, de sorte à pouvoir accéder à la partie basse de l’électronique. Cette partie permet le branchement du ou des cap- teurs sur les borniers à...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 5.3. Montage des compteurs sur les borniers à vis Une fois l’écrou et le joint de presse étoupe installés, les brins du câble du compteur peuvent être connectés aux borniers à vis du produit. Ci-dessous l’identification de chaque bornier: Note : 2 compteurs de même type au maximum peuvent être utilisés en parallèle.
Page 46
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Câblage pour compteurs 3 fils GND / Marron Masse / GND IMPULSION_1 / BF IMPULSION_1 / Blanc FRAUDE FRAUDE_1 / Vert Dans cette configuration, il est préférable d’activer l’entrée fraude de la voie A (registre 320 bit 3 = 1) et de désactiver la voie B (registre 320 bit 4=0) qui ne sert pas.
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 5.4. Fermeture du boîtier Une fois les étapes précédentes effectuées, vous pouvez fermer le boiter du produit. Procédure : Assurez-vous que le joint d’étanchéité est bien en place sur la semelle Clipser la carte électronique sur la semelle du boîtier.
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 6. INSTALLATION ET UTILISATION 6.1. Positionnement correct des émetteurs Deux règles sont primordiales pour une optimisation des portées radio. • La première consiste à positionner votre produit le plus haut possible. •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Pour retirer celui-ci, tirer vers le bas sur le levier jusqu’à ce que les Ergots ergots de blocage soient face à une partie dégagée et retirer le levier Partie dégagée 6.2.2 Fixation par vis Le produit est livré...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 6.2.3 Fixation Rail-DIN Ce système, intégré au boîtier, permet de fixer le produit sur un rail standard de 35mm • Pour installer le boîtier, placer les inserts supérieurs sur le rail et abaisser le produit pour le clipser •...
Version APP : V01.02.04 DISCLAIMER This document and the use of any information contained therein, is subject to the acceptance of the adeunis® terms and conditions. They can be downloaded from www.adeunis.com. adeunis® makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifi...
Page 53
Pulse - Guide utilisateur / User guide version V2.0.0 EU Declaration of Conformity adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Declare that the DoC is issued under our sole responsibility and belongs to the following product:...
Page 55
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 ENVIRONMENTAL RECOMMENDATIONS All superfl uous packaging materials have been eliminated. We have done everything possible to make it easy to separate the packaging into three types of materials: cardboard (box), expanded polystyrene (fi ller material) and polyethylene (packets, foam protective sheets).
Page 56
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS REGARDING USE • Before using the system, check that the power supply voltage shown in the user manual corresponds to your supply. If it doesn’t, please consult your supplier. •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 1. PRODUCT PRESENTATION IMPORTANT NOTE: the SIGFOX PULSE can only be started or restarted using a magnet. Description • sigfox Pulse is a ready to use radio transmitter that can be used to transform any type of meter into a wireless meter (smart meter). •...
The above values are estimations based on certain conditions of use and environment. They do not represent a commitment on the part of adeunis®. 1.4.3 Sensor compatibility Examples of sensors tested by adeunis® (non-exhaustive list): Type Name Type of sensor...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 1.4.4 Physical interface characteristics 1.4.4.01 INPUT Circuit The schematic diagram is the following: Absolute maximum ratings Unit Minimum input voltage - 0.7 Maximum input voltage Electrical characterisitcs (Typ.) Unit Minimum input voltage Maximum input voltage Equivalent Input pull-up kΩ...
Pulse - Guide utilisateur / User guide version V2.0.0 2. PRODUCT OPERATION 2.1. Global Operation Important: adeunis® use the most significant byte first format. The product has several operating modes: PARK MODE Presence of a magnet Command sending by on the product >6s...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 2.1.4 REPLI mode The product enters this very low consumption mode following the detection of a level of battery that is too low. In this mode the product wakes up every 5 seconds to make the red LED flash twice. The replacement of the battery (if the product is a replaceable battery version) followed by the application of the magnet takes the product out of this mode to return it to the operating mode.
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 2.2.2 Periodic transmission with history The product allows the accumulation of several successive meter values before the periodic transmission of the set of values according to the following scheme: Product in standby Historical Detected period rea-...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 2.2.3 Flow threshold alarm transmission The product allows the detection of the exceeding of a flow threshold for each counting entry according to the following scheme: Product in standby Detected Flow calcu- and valida- lation period...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 The settings associated with this mode of operation are: • Enabling and Configuring inputs (register 320) • History configuration (register S321) • Anti-bounce timer period (register S322) • Flow calculation period (register S325) •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Register Value encoding Value Result S320 Hexadecimal 0x39 Channel A : • Activated • Meter other than gas • Tamper input activated Channel B : • Activated • Gas meter •...
Page 67
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Product in standby Flow calcu- Pulse detec- Period of lation period ted and 24h reached reached ? validated Counting Calculation of flow Value pulse of the counter of zero flow period <(counter leakage) Value <...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Register Value encoding Value Result S320 Hexadecimal 0x39 Channel A : • Activated • Meter other than gas • Tamper input activated Channel B : • Activated • Gas meter •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 2.3. Operation of the LEDs Mode LED red state LED green state Transmission of frame (TEST mode only) ON during the transmission cycle Reception of frame (TEST mode only) ON during the reception of a downlink frame Product in Park mode Magnet detection process (1 to 6 seconds) ON from detection of the magnet up to a...
You should see the USB series device with a corresponding COM port number appear during connection. If you are not able to see a device of this type, you must install the USB driver for this device, available to download from our website: https://www.adeunis.com/produit/pulse/ Select: •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 3.2. Command mode Use a COM port terminal in order to communicate with the device. We use the HERCULES COM port soft terminal available to download for free by clicking on the following link: https://www.hw-group.com/products/hercules/index_en.html •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 3.3. AT commands A command starts with 2 ASCII characters: “AT”, followed by one or more characters and data (see the list below for the syntax of AT com- mands available on the modem). Each command must finish with a “CR”...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 3.4. Description of the registers On switching on the product works according to the last saved configuration (Factory Configuration if it is the first start, or if this configuration has not been changed). Commands such as Modification TTY<n>=<M>...
Page 74
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Configuration of the internal Hexadecimal Default value: 0x11 sensor (A et B) For channel A : • Bit 0 : channel A activation • Value 0: channel deactivated • Value 1: channel activated •...
Page 75
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Current value of meter - Decimal Default value: 0 channel A Min/max : 0 to (2 32-1 Unit : number of pulses In COMMAND mode, it is possible to write a new value in this register (for example an initialization value, an adjustment value ...).
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 3.4.2 Network registers These registers must be handled with caution because they could cause problems of communication or of non-compliance with the legislation in force. Registre Description Coding Details Number of repetitions in Decimal Default: 2 the case of a uplink frame...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 4. DESCRIPTION OF THE FRAMES 4.1. Uplink frame The uplink frames of the product to the network have a different size depending of the transmitted data. 4.1.1 Fixed bytes The first two bytes of the frame are systematically dedicated to indicate the frame code and the status as presented below:: Code Status PAYLOAD...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 4.1.2 Frames of information on the product configuration Following reception of a downlink frame with the code 0x01 or on switching to the operating mode (from the Park or Command Mode), the following frames (0x10, 0x11 et 0x12) representing the application configuration of the product are transmitted: 3 - 4 8 - 9...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 2 - 3 4 - 5 Code Status PAYLOAD 0x12 Cf Status S330 S331 0x12 0xA3 0x0003 0x0005 Description of the frame: • Bytes 2 and 3 : register 330, number of daily periods under leak threshold (channel A) •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 In the example in grey this gives: • Byte 2 : Alarmes = 0x19 soit (00011001) en binaire ce qu’y donne : • Bit 0 = 1 – Exceeding flow on channel A •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 4.1.7 Alarm frame This frame (0x47) is sent if the measured flow of one of the channels exceeds the configured threshold for this channel (registers S326 and S327). 2 to 3 4 to 5 Code Status...
Page 82
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 • Bytes 9 to 10 : Delta B1 : index variation of channel B during the time interval between 20 to 30 minutes after transmitting the previous frame. In the example in grey this gives: •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 In the example in grey this gives: • Byte 2: frame index: index of this frame in a multi-message sequence (always null in this configuration) = 3 (fourth frame) • Bytes 3 to 4 : Delta A4 : index variation of channel A during the time interval between 50 to 60 minutes after transmitting the previous frame = 0x074A so 1866 additional pulses •...
Page 84
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Frame 3/13 : 3 to 4 5 to 6 7 to 8 9 to 10 Code Status PAYLOAD 0x48 Cf Status Frame index Delta A2 Delta B2 Delta A3 Delta B3 0x48 0xA3 0x0100...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 0x48 0xA3 0x074A 0x003B 0x0010 0x0021 3 to 4 5 to 6 7 to 8 9 to 10 Code Status PAYLOAD 0x48 Cf Status Frame index Delta A16 Delta B16 Delta A17 Delta B17 0x48...
(RX window) for a maximum of 30 seconds, in accordance with the diagram below: The configuration of the sending policy of the acknowledgement request in the adeunis® product differs according to whether the product is in periodic or event mode: •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 4.2.2 Network configuration request frame This frame allows to inform the product via the network that it must resend the network configuration uplink frame (0x20). Code PAYLOAD 0x02 4.2.3 Frame for adding an offset to pulse counters These frames (0x03 and 0x04) allows to add an offset to the counter value on each channel.
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Description of the frame: • Bytes 1 to N : CONFIDX (8bits): indice of the register to be sent. The corresponding register is 300 + CONFIDX value. For example, if CONFID1 = 20, the product will send back the value of register number 320. The associated uplink frame has the code 0x31 (see paragraphe 4.1.5).
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 5. PREPARATION 5.1. Dismantling the case The product is supplied disassembled such that the lower electronic part can be accessed. This part is where the meter or meters are connected to the screw terminals and where the configuration switches can be accessed.
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 5.3. Mounting the counters on the screw terminals Once the nut and packing seal are installed, the strands of the meter cable can be connected to the screw terminals of the product. Below is the identification of each terminal block: Note: Up to 2 meters of the same type can be used in parallel.
Page 91
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 Meter with 3-wire output GND / Brown GROUND / GND IMPULSE_1 / BF IMPULSE_1 / White TAMPER TAMPER_1 / Green In this configuration, it is prefered to activate input TAMPER of A-channel (register 320 bit 3 = 1) and deactivate B-channel (register 320 bit 4=0) which is not no used.
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 5.4. Closing the casing Once previous stages have been carried out, you can close the casing of the sigfox Pulse Procedure: Make sure that the seal is properly positioned on the base Clip the electronic board onto the casing’s base.
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 6. INSTALLATION AND USE 6.1. Correct positioning of the product There are two key rules for optimising radio ranges. • The first one consists of positioning your product as high as possible. •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 To optimise fastening onto a tube or mast, we recommend you Pins remove the Rail-DIN locking/unlocking lever. To remove it, pull the lever down until the locking pins are opposite Freed up part a freed-up part and then remove the lever 6.2.2 Fixing with screws...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 6.2.3 DIN-Rail fixing This system, integrated into the casing, enables the product unit to be fastened onto a standard 35 mm rail. • To fit the casing, place the upper inserts on the rail and lower the product to clip it into position. •...
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 DEUTSCH Vorschriften Page of 100...
Page 97
Recht vor, jederzeit und ohne Vorankündigung Änderungen an den Produktspezifi kationen und -beschreibungen vorzunehmen. adeunis® behält sich alle Rechte an diesem Dokument und den darin enthaltenen Informationen vor. Die Ver- vielfältigung, Nutzung oder Weiterverbreitung an Dritte ohne ausdrückliche Genehmigung ist streng untersagt.
Page 98
Programmiersprachen, unter Verwendung jeglicher elektrischer, mechanischer, magnetischer, optischer, manueller Geräte oder anderer Methoden, ist untersagt. adeunis® behält sich das Recht vor, ohne schriftliche Bekanntgabe und ohne ausdrückliches Verlangen seiner Kun- den die technischen Spezifi kationen oder Funktionen seiner Produkte zu ändern und sicherzustellen, dass die ihnen zur Verfügung gestellten Informationen gültig sind.
Page 99
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 UMWELTSCHUTZHINWEISE Es wurden alle überfl üssigen Verpackungsmaterialien vermieden. Wir haben uns bemüht, dass die Verpackung leicht in drei Materialarten getrennt werden kann: Pappe (Schachtel), expandiertes Polystyrol (Puff ermaterial) und Polyethylen (Tüten, Schaumstoff -Schutzlage). Ihr Gerät besteht aus recycelbaren Materialien, die im Falle einer Demontage durch ein Fachunternehmen wiederverwendet werden können.
Page 100
sigfox Pulse - Guide utilisateur / User guide version V2.0.0 GEBRAUCHSHINWEISE • Überprüfen Sie vor Benutzung des Systems, ob die in dessen Betriebsanleitung angegebene Versorgungsspan- nung mit Ihrer Stromquelle übereinstimmt. Falls nicht, wenden Sie sich an Ihren Lieferanten. • Stellen Sie das Gerät auf eine ebene, feste und stabile Oberfl äche. •...