Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

Electrical connection
230 V - 50 Hz
General
When the appliance does not have a
connecting cable and plug, then it may be
connected to the mains only by an approved
installer.
Note:
The power rating and required mains voltage
are shown on the rating plate at the back of
the appliance. Connection should take place
according to national and local regulations.
If the input of the appliance exceeds 3 kW, the
appliance has to be connected to an outlet
with a rated current exceeding 13 Amp.
Technical data
Types
60 cm
45 cm
Connected load kW
2,0
2,0
Dimensions
Max. height
mm
870
870
Min. height
mm
820
820
Width
mm
596
446
Depth
mm
550
550
Door panel:
Max. height
mm
720
720
Min. height
mm
650
650
Width
mm
598
448
Plinth:
Max. height
mm
170
170
Min. height
mm
100
100
What else you should watch out for
Always fit tap, drainage and earthed
plug/wall socket within reach.
Make sure that the skirting-board can be
removed. It must be possible to take the
dishwasher out of its recess for
maintenance or repair work.
Connect water inlet hose/aquastop to a
self-venting water tap with a 3/4" screw
connection.
Make sure that no dirt remains in a newly-
installed water pipe.
The dishwasher may be connected either
to a cold-water tap or to a hot-water tap
(maximum 60 °C).
If you connect the dishwasher to a hot-
water tap, the washing time will be
reduced by about twenty minutes.
However, the dishwasher will wash less
efficiently. The 45 °C programme will
therefore be carried out at a slightly higher
temperature.
Do not drill holes in the door or walls. The
dishwasher could be damaged beyond
repair.
Building-in
Remove the wooden platform on which the
machine is standing by unscrewing the
screws.
Fix the adjustable feet with the lock nuts
beneath the side panels of the machine.

Publicité

Table des Matières
loading

Table des Matières