1.2 Installation
Fuels
Low smoke, trouble-free operation of the stove and a supply of heat at the nominal
level with a chimney draught of 12 Pa are only guaranteed when you use the following
fuels and no others.
Only use natural, dry chopped firewood with a remaining humidity of max. 20%.
Hardwood
Softwood
Wood briquette according to DIN 51731
With the primary air damper, do you adjust the rated output.
There may be engaged in only the settings and fuel quantities are
given that correspond to your licensed or purchased device.
Adjustment:
Warning up, kindling
Wood
Nominal heat output
Putting out of working order
Filling quantities 6,0 kW
- Split billet: max. length: 25cm, max. 2 billets per filling, appr. 1,4 kg
IT IS NOT ALLOWED to burn waste, fine chipping, bark, wood handled with preven-
tive chemicals, furthermore paper, coal and cardboard. For kindling, please use wood
scrapings or fire cubes, but never use liquid auxiliaries!
Do not use liquid lighting aids such as gasoline, gasoline-like lamp oils, petroleum,
charcoal lighters, ethyl alcohol or similar liquids to start or "relight" a fire in the space
heater!
The first kindling
At the first fire set-up could be a little smoke, but is not dangerous, normal!
In this time, please ventilate the room carefully!
Warning! Upon the first kindling, smoke and unpleasant smell may be generat-
ed. Always ensure the proper ventilation of the room (by opening windows and
doors), and heat the fireplace at maximum rated heating performance. If with the
first heating the maximum temperature is not reached, the above-mentioned
effects may as well arise later on.
Fuel Type
Setting of the primary air
Tabelle 1
Calorific value approx.
kWh/kg
4,0 – 4,2
4,3 – 4,5
5,0 – 5,2
regulator
6,0 kW
A
H
close
21
Burning time
-
ca. 0,75 h
-