f) Activate/Deactivate Protection from Incorrect Input
Here, you can programme whether the code lock should react to incorrect input
with a key lock or not (basic setting: deactivated).
When the protection function is activated, the code lock locks any input for a
duration of about 30 seconds if either a code has been entered incorrectly 5x or
20 digits in sequence do not match any code.
The protection to be used (5 incorrect codes or 20 incorrect digits) can
be selected as described in chapter 8 g).
Start the programming mode as described in chapter 8. a). The yellow LED must
be lit.
Then enter:
*51
Every call of the programming toggles the protection function.
Example:
If the protection function was off, it is now on (or vice versa).
Check the function for activation or deactivation after leaving program-
ming mode. There is no separate display for it.
If desired, you can programme other settings now or leave the programming
mode with the pound key (#).
32